Beijer Electronics iX T4A EN User Manual
Page 5
Safety Precautions
•
All devices have to be supplied by a Class 2 power supply.
Warning:
Do not disconnect equipment unless power has been removed or the area is
known to be non-hazardous
•
For Canada also AVERTISSEMENT – AVANT DE DECONNECTER
L’EQUIPEMENT, COUPER LE COURANT OUS’ASSURER QUE
L‘EMPLACEMENT EST DESIGNE NON DANGEREUX.
Warning:
Only UL and cUL approved expansion units are allowed to be connected to
the port designated “EXPANSION”. At the moment there are no such units
evaluated or allowed.
Warning:
Do not replace expansion unit unless power has been switched off or the area
is known to be non-hazardous.
•
This product contains a battery; this must only be changed in an area known
to be non-hazardous.
•
Replace the battery with a BR 2032 battery. Use of another type of battery
may present a risk of fire or explosion.
Warning:
Battery may explode if mistreated. Do not recharge, disassemble or dispose
of in fire.
•
For use on a flat surface of a type 4X enclosure indoor use only.
•
Use 75 degree conductors only
•
Use copper conductors only
•
To make wiring connections to the power supply connector, follow the table
with cable and torque specifications below:
Terminal Block No.
Wire Size AWG
TQ Lb.In.
X1/X100 Phoenix connectors
AWG 30–12
5–7
X1/X100 Anytek connectors
AWG 24–12
3.5
•
These devices are Class 2 supplied programmable controllers (industrial PCs)
for the use in industrial control equipment and are intended to be (front)
panel mounted (Type 1 and 4x for indoor use only).
Beijer Electronics, MAEN015F
5