Plumbing requirements, Mechanical installation of built-in units, Drop-in version installation – Power Soak 33639 SILVERWARE PRE-WASHING SYSTEM INSTALLATION MANUAL User Manual
Page 3

3
Plumbing Requirements
The plumbing required for your system depends on the type of system you have
purchased:
• Mobile units must have a floor sink nearby that they can be moved to for
emptying waste water. In addition, some mobile units are equipped with
faucets that will require a temperature regulated 1/2 NPT potable water
flexible connection.
• Free-standing stationary units and built-in units must have their drains
permanently connected to the building scullery sewer system. In addition,
these units are equipped with faucets that will require a temperature
regulated 1/2 NPT potable water connection.
Mechanical Installation of Built-in Units
Both the Drop-in and the Weld-in versions of the Power Soak Silverware Pre-
washing System are designed to be installed in existing dish tables. Installation of
both types is very similar with the main difference being that the Drop-in version
requires no field welding.
Drop-in Version Installation
Review the drawings that came with the unit to confirm that the location chosen for
the system is adequate with respect to:
• Drain proximity
• Electrical power proximity
• Adequate space on the dish table top for the tank and the faucet
• Appropriate location for the control box bracket
• Absence of ribs or other features on the underside of the selected dish table
location