Heritage I12 Computer, Single Vat (PP11370) and Dual Vat (PP11372)
Quick Reference Card
L20-320 Rev 0 10/07
F
u
n
c
ti
o
n
K
e
y
s
P
r
o
g
r
a
m
m
in
g
FIRST LEVEL PROGRAMMING
ENTER PROGRAM
Press
key, display show [PROGRAM], If PASSWORD IS REQUIRED, and you are unable
to remember the set password use (6684).
SET TEMPERATURE
Single or Dual Vat (left side ) - Press
Enter Desired Temperature.
Dual Vat (right side) - Press
Enter Desired Temperature.
To SAVE and CONTINUE Press
, to EXIT First Level Programming Press
Again.
SET TIME(s) .. Press
, display shows [SELECT] [PRODUCT] ,Press any Product Key [L,1,2,3,4,5,6,7,8,9,0,R].
COOK TIME (CKn mm:ss] Enter Time and Press
to proceed to SHAKE TIME (SHn mm:ss] Enter Time and
Press
to proceed to HOLD TIME (HDn mm:ss] Enter Time and Press
to proceed to HOLD PRE-ALARM
(PAn mm:ss] Enter Time and Press
to return to [SELECT] [TIME] , repeat for other product keys.
To SAVE and CONTINUE Press
, to EXIT First Level Programming Press
Again.
SECOND LEVEL PROGRAMMING
ENTER PROGRAM
Press
key, display shows [PROGRAM], If PASSWORD IS REQUIRED, and you are
unable to remember the set password use (6684). Then press
you have now entered the upper level programming,
all the useable function keys will be lighted and the display will show [SELECT OPTIONS].
NOTE: Any time
is used to save a setting,
must be pressed to return to [SELECT OPTIONS].
FAHRENHEIT / CELCIUS – Toggle between Fahrenheit and Celcius scale by pressing the
key
Change is saved by pressing the
key to set
SET PASSWORD – Press
to choose [PASS REQ] or [NO PASS]. If password is chosen then
press
, current password displays. Use the number keys to enter new password and press
to set.
BEEPER VOLUME & TONE – Press
to toggle between levels 1,2,3 & Tone(1,2,3) and press
to set.
LANGUAGE – Press
to toggle between different languages and press
to set.
MELT CYCLE – Press
to toggle [NO MELT], [SOLID], or [LIQUID] and press
to set.
RECOVERY TIME – Press
to display [F065 LXXX], “F” is Factory time and lastest time is “LXXX”
CONTROL/TIMER (Single or Dual-left side) – Press
to switch control to timer mode,press
to set.
CONTROL/ TIMER (Dual Tank-right side) – Press
to switch control to timer mode , press
to set.
To SAVE and CONTINUE Press
, to EXIT SECOND Level Programming Press
Again.
OTHER DISPLAYS:
[PROBE OP] [OPEN] If probe is detected open, normal heating and cooking activities are suspended.
[HIGH TMP] [HIGH TMP] If vat temperature has exceeded set temperature by 40°F (22°C), or an absolute of 410°F (210°C) max.
[DRAINING] [TURN OFF] Drain valve has been opened, Heat control is turned off. To restore to normal operation, close the drain
valve. Display will show [TURN OFF] [TURN OFF]. Turn controller off, and refill the vat.
[HEAT] [FAILURE] OR [IGNITION] [FAILURE] Heating system failed to respond due to a tripped high temperature limit switch and
is in need of resetting. For gas models, the pilot failed to light, flame ignition detection is marginal or draft protector tripped on SCB.
[SYSTEM] [FAILURE] If probe is detected as a short circuit, normal heating and cooking activities are suspended.