4.2.2.3 PC Settings
IP Address: IP Address of the CN4490 unit.
Port: Port number of the CN4490 unit, the Port number is always 2101.
System Config: Type of CN4490 network to be configured. Valid choices are Point-to-Point
(one Server and one Client) or Point-to-Multipoint (one Server and multiple Clients).
Attention: When setting up a Point-to-Point network the Server’s Destination address must
be set to the Client’s MAC Address.
4.2.2.4 Programming the CN4490 units
1. Connect the CN4490 unit to the network.
2. Connect the power supply to the CN4490 unit. Make sure the Pwr LED is on.
3. Start the CN4490 Configuration Utility.
4. Select TCP/IP Select on the PC Settings Frame.
5. Enter the IP Address of the CN4490 that needs to be configured.
6. Select the System Configuration for the CN4490 network, Point-to-Point (one Server
and one Client) or Point-to-Multipoint (one Server and multiple Clients).
7. Select
Read Radio to display the current settings of the CN4490 unit.
8. Change desired settings.
9. After all changes have been made, select Write Radio to save the changes.
Note: The Show Defaults button can be used to display the default Radio settings.