A.J. Antunes & Co DFL 8743130044 User Manual
Dfl installation information, Dimensions wiring diagram, Specifications
A. J. ANTUNES & CO. www.ajantunes.com 180 Kehoe Blvd., Carol Stream, Illinois 60188
Dimensions
Wiring Diagram
IMPORTANT
Please read these instructions carefully to assure
correct installation. This equipment must be
installed by a licensed electrician. Prior to being
put into operation, check all wiring and function of
the unit.
DFL Installation Information
Specifications
Sensor: Thermistor, Length 10 Ft. (3 m)
Accuracy: +/-3% of Set Point
Power Input: 24 VAC; 120 VAC, 230 VAC (Optional),
60 Hz.
Control Operation: Low Temperature - Closes on Rise
High Temperature - Opens on Rise
Output Ratings: Two - S.P.S.T. Relays, N.O.,
230 VAC Load
15 Amps @ 120 VAC
(Resistive Load)
SPDT (Optional)
Temperature Range: Fan: 80ºF to 120ºF (25ºC to 50ºC)
High Limit: 150ºF to 300ºF (65ºC to 145ºC)
Differential Adjustment Range:
Fan: 5ºF to 50ºF
High Limit: 1ºF to 15ºF
Operating Temperature: -30º to 140ºF (-35º to 60ºC)
Connections: 1/4” Quick Connects
6” Wire Leads (optional)
Enclosure: Aluminum 5.12” Ht. x 5.9” Wd. x 3.10” Dp.
“C” Bracket, Open Board
Enclosure w/Conduit Knockout (optional)
Shipping Weight: 2 lbs. (.9 kg)
Connections
Thermistor Inputs: (100 kohm @ 25°C)
Fan: T7 & T8
High Limit: T4 & T5 (optional)
Power Input: 24 VAC (optional 120 or 230 VAC)
Vin: T3 & T4
Fan Relay: N.O. & COM. On relay body (optional N.C.)
High Limit Relay: N.O. & COM. On relay body (optional
N.C.)
1-630-784-1000 Fax: 630-784-1651
Page 1 of 4
P/N 1011096 06/10
1-800-253-2991
808000135
415
2.56”
(65 mm)
5.12”
(130 mm)
Ø.187”
(2 PL'S)
40
MODEL DFL
50
10
°F
HYS
110
40
FAN
120
°C
80
°F
30
20
30
25
90
35
50
45
FAN
100
85
95
65
°F
150
170
75
°C
300
ALARM
250
270
125
145
135
105
115
190
HIGH LIMIT
230
210
5.430”
(138 mm)
5.93”
(151 mm)
3.10”
(79 mm)
808000135
415
2.56”
(65 mm)
5.12”
(130 mm)
Ø.187”
(2 PL'S)
40
MODEL DFL
50
10
°F
HYS
110
40
FAN
120
°C
80
°F
30
20
30
25
90
35
50
45
FAN
100
85
95
65
°F
150
170
75
°C
300
ALARM
250
270
125
145
135
105
115
190
HIGH LIMIT
230
210
5.430”
(138 mm)
5.93”
(151 mm)
3.10”
(79 mm)
NOTE: Dimensions are for reference only.
Sensor
Input
T7
T8
Sensor
Input
T4
T5
High
Limit
Relay
N.C.
COM
N.O.
Fan
Relay
N.C.
COM
N.O.
Vin
T3
T2
DFL
System Shutdown
Over Temperature
Contacts
Fan
Control
Contacts
Input Power
(24 VAC)
FAN
FAN
HIGH
LIMIT
TRANSFORMER
120/230 VAC
to 24 VAC
120/130 VAC
(Neutral)
120/230 VAC
(Hot)
Temperature Sensors