beautypg.com

Uf-216 water filtration system, Important safety information, A.j. antunes & co – A.J. Antunes & Co UF-216 9700435 User Manual

Page 4

background image

UF-216 water Filtration system

4

A.J. Antunes & Co.

P/N 1011078 Rev. B 03/12

ImpOrtant safety InfOrmatIOn

In addition to the warnings and cautions in this manual,

use the following guidelines for safe operation of the unit:
• Read all instructions before using equipment.
• Install or locate the equipment only for its intended

use as described in this manual. Do NOT use

corrosive chemicals in this equipment.

• Do NOT operate this equipment if it has a damaged

cord or plug; if it is not working properly, or if it has

been damaged or dropped.

• This equipment should be serviced by qualfied per-

sonnel only. Contact A.J. Antunes & Co. for repair.

• Do NOT immerse cord or plug in water.
• Keep cord away from heated surfaces.
The following warnings and cautions appear throughout

this manual and should be carefully observed:
• Unplug the power cord before performing any

service or maintenance on the unit.

• All electrical connections must be in accordance

with local electrical codes and any other applicable

codes.

• WARNINg eleCTRICAl ShOCK hAzARD.

FAILURE TO FOLLOW THESE INSTRUCTIONS

COUlD ReSUlT IN SeRIOUS INjURy OR DeATh.

- Do NOT modify the power supply cord plug. If

it does not fit the outlet, have a proper outlet

installed by a qualified electrician.

- Do NOT use an extension cord with this unit.

• If the supply cord is damaged, it must be replaced

by the manufacturer or its service agent or a simi-

larly qualified person.

• This equipment is to be installed to comply with the

local plumbing code and any other applicable code.

• Water pressure must not exceed 100 psig (690

kPa). To reduce water pressure, install a water

pressure regulator and set water pressure to suit

application.

• The trans membrane pressure (inlet water pres-

sure minus the permeate water pressure) must not

exceed 45 psi (310 kPa).

• System should be supplied only with cold water.
• Commonwealth of Massachusetts Plumbing Code

248 CMR shall be adhered to. The use of saddle

valves are not permitted, please consult your local

plumber.

• A ground fault circuit interrupter (gFCI) must be

installed on the circuit to this system

• When installed on metallic plumbing, a properly

sized electrical bonding jumper must be installed

across the inlet and outlet pipes serving this device.