beautypg.com

Wiring – Aqua Products CC-350 User Manual

Page 7

background image

7

W i r i n g t h e C o n t r o l B o x t o S t a n d a r d T i m e r

CAUTION: Check whether your chlorine generator operates on 120 volts or 240 volts

(see label on the left side of the Control Box), and be sure to wire the system accordingly.

CAUTION: It is critical to wire the chlorine generator in such a way that it can only

operate when the pump is operating (i.e. load side). See instructions below for details.

















1. Attach the green ground wire to the grounding lug or bar.
2. Connect the black Load wire from the chlorine generator to Load 1 of the time clock.
3. If wiring a 240 Volt generator, connect the third wire to Load 2 of the time clock. If wiring a 120 Volt

generator, connect the third wire to the Neutral lug or bar on the timer (see label on the left side of the
Control Box to confirm voltage).

4. Bonding is recommended and may be required by local code. The bonding lug is found on the bottom

of the Control Box.

W i r i n g t h e C o n t r o l B o x t o A u t o m a t e d S y s t e m s

CAUTION: Check whether your chlorine generator operates on 120 volts or 240 volts

(see label on the left side of the Control Box), and be sure to wire the system accordingly.

CAUTION: It is critical to wire the chlorine generator in such a way that it can only

operate when the pump is operating (i.e. load side). See instructions below for details.


The Comfort-Chlor Chlorine Generator can operate with virtually any automated control system as an
auxiliary.

1. Attach the green ground wire to the grounding lug or bar.
2. Connect jumper wires from the Load side of the Circulation Pump Relay to the Line side of an

Auxiliary Relay as depicted in the relevant diagram below (based on the voltage used by the
pump and the chlorine generator) and in accordance with instructions of the automatic
controller manufacturer.

3. Connect the Comfort-Chlor Chlorine Generator to the Load 1 & 2 connectors of the Auxiliary

Relay to control the generator’s operation.

4. Bonding is recommended and may be required by local code. The bonding lug is found on

the bottom of the Control Box.

5. Set the chlorine generator to 100% power, and program the Aux Relay to run the chlorine

generator as needed. (e.g. 100%, 50%, 25% of the time the pump is running).

This manual is related to the following products: