beautypg.com

Battery, Battery condition, Battery change – Flytec 6010/6005 User Manual

Page 24: Malfunction / resetting the instrument

background image

Operating Instruction Flytec 6005/6010

23

Battery

The 6005/6010 can operate on 2 AA 1.5V Alkaline or 2 AA 1.2V NiMh batteries. The
battery compartment is accessed by removing the slotted screw in the battery door on the
rear of the housing.

Battery condition

During the switching-on process, the instrument will briefly show the relative battery
condition in the analog vario scale (Po shown in the digital vario display) where ½ scale
equates roughly to batteries that have ½ of their life remaining. When the 6005/6010 is in
normal operation the condition of the battery is continuously shown in the lower window of
the LCD.

empty

50%

full

Battery change

When it becomes necessary to change the batteries verify that the 6005/10 is switched off!
Remove one of the spent batteries and replace with a fresh one, then remove the other
spent battery and replace it with a fresh one. If the power interruption is less than 30-
seconds the time and date will be preserved and will not need to be reset. If the above
procedure is followed there will be minimal power interruption to the CPU. If the 6005/10
does not show the time/date after replacing the batteries please follow the procedure in the
section Malfunction/Resetting the Instrument.

Malfunction / Resetting the Instrument

In the event that the 6005/10 behaves oddly or gives an error message, remove the
batteries for 5-minutes, then press and hold the on/off key for 1-minute. After the batteries
are replaced, the instrument performs a self check. If the problem persists, contact your
local Flytec Distributor (www.flytec.ch, www.flytec.com, www.flytec.fr) to determine the
appropriate service location to send your instrument for repair.

Lo Batt

Battery voltage less than 2.1 V.
Please change batteries.

Temperature field

Lo

Temperature is less than -72.4°F (-50° C).

Temperature field

Hi

Temperature is higher than 168.8°F (76° C).

* Temperature field

Err

Temperature sensor is faulty.

Speed display

Hi

Speed is higher than 99 mph (159 km/h).

* Speed display

Err

Frequency converter for measuring speed is faulty.

* AdErr

Analog/Digital -converter for measuring pressure is faulty.