INPUT WIRING
Balanced Inputs
Balanced input wiring requires two conductors with shield (22 gauge is the most common). The use of
crimp type spade lugs is highly recommended for permanent installations. At the input section located on
the rear of the CP700, wire the "hot"/positive lead to the "+" terminal, the "cold"/negative lead to the "-"
terminal and the shield/drain to the "ground" terminal.
The XLR inputs (+4dB balanced line level) can be utilized with standard 3-pin XLR male to female patch
cables to accommodate outputs from a mixer, equalizer or crossover when the CP700 is used as a
portable sound system amplifi er (Figure 3).
Figure 3
LEVEL
-0
0
5
6
4
0
3
2
2
6
22
18 16 14 1
2
1
0
8
6
4
2
0
PROTECT
LIMIT
SIGNAL
CH-1
PROTECT
LIMIT
SIGNAL
CH-2
CH-2
+
THRU
IN
GND
LEVEL
AMPLIFIER INPUTS
CH-1
THRU
IN
+
-
-
GND
-0
0
5
6
4
0
3
2
2
6
22
18 16 14 1
2
1
0
8
6
4
2
0
Black (-)
Shield
White (+)
Black (-)
Shield
White (+)