10 connecting the components to the controller, Hh.lll.lll.hh.lll – Sol TP Series Top of Pole Mount Lighting User Manual
Page 12
12
rev.1011 MKTG-IM-TP-12-002
Installation and Owner’s Manual | TP Series Solar LED Lighting System
2.10 Connecting the Components to the Controller
The aiSUN™ and EternO® 4 controller are unique solar charging and LED luminaire
controllers. Each device includes an intelligent solar light CPU that performs the following:
• Charging the battery: The controller modulates and controls the electricity generated
by the PV module, to properly and safely charge the NRGLife™ battery.
• Operating the LED Luminaire: The controller switches the LED luminaire on after
sunset and off before sunrise. The particular operating mode that is used
(see below) is factory-set.
Determining the Factory-Set LED Luminaire Operating Mode
The operating mode for the TP Series lighting system is set at the factory according to
requirements specified for your location. The operating mode that was set for your TP
Series lighting system is included in the information provided on the product label:
HH.LLL.LLL.HH.LLL
Please call Sol Customer Service at +1-772-286-9461 if you believe the operating mode for
your TP Series lighting system is not configured correctly. Examples of operating modes
for the TP Series lighting system are shown in Figure 14.
Number of hours (
HH)
light operates at
intensity
LLL% after dusk
Number of hours (
HH)
light operates at
intensity
LLL% before dawn
Intensity
LLL% of light during
the intervening period
Dusk to Dawn
DD.100.000.00.000
Programmed
06.100.000.00.000
Split Night With Dimming
04.100.050.03.000
FIGURE 14
EXAMPLES OF OPERATING MODES FOR THE TP SERIES LIGHTING SYSTEM