Compliance, H2tu-c compliance, H2tu-r compliance – ADTRAN HDSL2 User Manual
Page 14: H2tu-c compliance h2tu-r compliance, Table 4, Compliance codes, h2tu-c, Table 5, Compliance codes, h2tu-r

Product Description
HDSL2 for General Distribution Installation and Maintenance Practice
4
61223HDSL2L2-5B
Compliance
ADTRAN HDSL2 modules are NRTL listed to the applicable UL standards. The HDSL2
modules are to be installed in a restricted access location and in a type “B” or “E” enclosure
only.
These devices comply with Part 15 of the FCC rules. Operation is subject to the following two
conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including interference that may cause
undesired operation.
Changes or modifications not expressly approved by ADTRAN could void the user’s authority
to operate this equipment.
H2TU-C Compliance
shows the compliance codes for the H2TU-C modules.
The H2TU-C modules provide span powering voltage (negative only with respect to ground,
–190 VDC nominal, GFI protection <5 mA) and meets requirements of Bellcore
GR-1089-CORE (Class A2) and ANSI T1.418-2002.
H2TU-R Compliance
shows the compliance codes for the H2TU-R modules.
The H2TU-R modules must only be installed in shelves or mountings that utilize pin 27 of the
edge connector as a frame ground.
Table 4. Compliance Codes, H2TU-C
Code
Input
Output
Power Code (PC)
F
C
Telecommunication Code (TC)
–
X
Installation Code (IC)
A
–
Table 5. Compliance Codes, H2TU-R
Code
Input
Output
Power Code (PC)
C
C
Telecommunication Code (TC)
X
X
Installation Code (IC)
A
–