Agilent 85108A pulsed-RF network analyzer system 
(2 GHz to 20 GHz) 
Based on an 8510C with Option 008, this system
provides the capability to measure the amplitude
and phase response of a device or component
being driven with a pulsed-RF input signal. The
instruments are integrated in a 1600 mm system
rack. It is fully tested and a complete system verifi-
cation is performed prior to shipment from the 
factory. Installation is included at no additional
charge. 
System components include:
8510C network analyzer with Option 008
(pulsed-RF measurement capability)
85110A test set
1600 mm rack
83622B synthesizer with Options 001/004/008
83623L synthesizer with Options 004/008 
Calibration kits and test port cables in the
appropriate connector interface are not
included and must be ordered separately. 
Frequency range (select one)
• 85108A-STD 2 - 20 GHz
• 85108A-E63 500 MHz - 20 GHz
• 85108A-F61 2 - 50 GHz with front panel connectors
• 85108A-F62 45 MHz - 50 GHz
Features
• 8510C-010 Add time domain
Voltage options
• 85108A-115 110/120 V line voltage operation
• 85108A-230 220/240 V line voltage operation
Extended service options are available.
Agilent 85108L pulsed-RF network analyzer system 
(45 MHz to 2 GHz)
Based on an 8510C with Option 008, this system
provides the capability to measure the amplitude
and phase response of a device or component
being driven with a pulsed-RF input signal. The
instruments are integrated in a 1600 mm system
rack, the system is fully tested, and a complete sys-
tem verification is performed prior to shipment
from the factory. Installation is included at no
additional charge. 
System components include:
8510C network analyzer with Option 008
(pulsed-RF measurement capability)
85110L test set
1600 mm rack
83620B synthesizer with Options
001/004/008/H80
83620B synthesizer with Options 004/008/H80 
Calibration kits and test port cables in the
appropriate connector interface are not
included and must be ordered separately.
Features
• 8510C-010 Add time domain
Voltage options
• 85108L-115 110/120 V line voltage operation
• 85108L-230 220/240 V line voltage operation
Extended service options are available.
Agilent 85122A high frequency device modeling system 
(45 MHz to 20 GHz)
When combined with the 85190 series high 
frequency IC-CAP software, along with Cascade
probes or ICM fixtures, the 85122A can be used to
model BJT, FET, MOS, and diode devices. All
instruments are integrated in a 1600 mm system
rack prior to shipment from the factory.
Installation is included at no additional charge.
System components include:
8510C network analyzer 
8514B test set 
83621B synthesizer 
11612A Option K10/K20 force/sense bias networks 
4156C DC source/monitor 
85131F cable set 
1600 mm rack 
Probes, fixtures, calibration kits, 85190 series
software, and workstation must be ordered 
separately.
• Option 230 provides system cabinet set up for
220/240 V operation
Custom configurations available to meet other 
frequency coverage and power requirements.