Declaration of conformity, Arc pinout, Arc distance table – Symetrix Jupiter User Manual
Page 3
3
QUICK START GUIDE: Jupiter 4, Jupiter 8, Jupiter 12
Declaration of Conformity
6408 216th Street SW
|
Mountlake Terrace, WA 98043 USA
T
+1.425.778.7728
F
+1.425.778.7727
|
www.symetrix.co
ARC Pinout
The RJ45 jack distributes power and RS485 data to one
or more ARC devices. Uses standard straight-through UTP
CAT5/6 cabling.
1
!
Warning! Refer to the RJ45 Warning for compatibility
information.
The Symetrix ARC-PSe provides serial control and power
distribution over standard CAT5/6 cable for systems with more
than 4 ARCs, or, when any number of ARCs are located long
distances from a Integrator Series, Jupiter or SymNet DSP unit.
Port Settings: 38.4 kbaud, 8 data bits, 1 stop bit, no parity, no
flow control.
The following table provides at-a-glance cable length limitations
based on DC power (the table is not relevant if only RS-485 is
distributed) and assumes 24 gauge CAT5/6 cabling. The lengths
for multiple ARCs on a single chain assume equal distance for
each cable segment between ARCs. Table is intended for quick
reference only. For more detailed configuration scenarios
Special note: for multiple ARCs on single chain, the listed value
is assumed to be the cable length between each device. For
example, a value of 600’ means 600’ between the DSP unit and
the first ARC, 600’ between the first and second ARCs, etc. The
total cable length will be the listed segment length multiplied by the
number of ARCs on the chain.
number of ARCs
on chain
ARC-2e/ARC-2i ARC-K1e ARC-SW4e ARC-SWK ARC-XLR ARC-MIC
1
1000'
3250'
3250'
1800'
3250'
3250'
2
370'
1200'
1200'
600'
1200'
1200'
3
190'
600'
600'
325'
600'
600'
4
115'
350'
350'
200'
360'
360'
CABLE SEGMENT LENGTH LIMITATIONS FOR ARC POWER OVER CAT-5/6 CABLE
ARC TYPE
ARC-EXK ARC-EX4e
1
4
2
3
1
3
2
3
2
3
ARC-SWK
ARC-MIC
ARC-XLR
MAXIMUM NUMBER OF ARC EXPANSIONS UNITS POSSIBLE PER
MODULAR ARC BASE UNIT
MODULAR ARC BASE UNIT
ARC-K1e
ARC-SW4e
Declaration of Conformity
We,
Symetrix Incorporated, 6408 216th St. SW,
Mountlake Terrace, Washington, USA, declare under our
sole responsibility that the product:
Jupiter•4, Jupiter•8, and Jupiter•12
to which this declaration relates, is in conformity with the
following standards:
IEC 60065,
EN 55103-1, EN 55103-2, FCC Part 15, RoHS
The technical construction file is maintained at:
Symetrix, Inc.
6408 216th St. SW
Mountlake Terrace, WA, 98043 USA
The authorized representative located within the European
Community is:
World Marketing Associates
P.O. Box 100
St. Austell, Cornwall, PL26 6YU, U.K.
Date of issue: April 26, 2010
Place of issue: Mountlake Terrace, Washington, USA
Authorized signature:
Dane Butcher, President, Symetrix Incorporated.
ARC Distance Table
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1 • AUDIO (+)
2 • AUDIO (-)
3 • COMMON GROUND
4 • RS-485 DATA (A)
5 • RS-485 DATA (B)
6 • COMMON GROUND
7 • POWER (+V)
8 • POWER (+V)
Note:
The ARC Audio line may be grounded at the
Symetrix rack-mount device and the ARC wall panel
to provide additional distance.
ARC PORT PINOUT
8
7
6
5
4
3
2
1
Pair 1
Pair 3
Pair 4
Pair 2