beautypg.com

Declaration of conformity, Arc pinout, Arc distance table – Symetrix Jupiter User Manual

Page 3

background image

3

QUICK START GUIDE: Jupiter 4, Jupiter 8, Jupiter 12

Declaration of Conformity

6408 216th Street SW

|

Mountlake Terrace, WA 98043 USA

T

+1.425.778.7728

F

+1.425.778.7727

|

www.symetrix.co

ARC Pinout

The RJ45 jack distributes power and RS485 data to one

or more ARC devices. Uses standard straight-through UTP

CAT5/6 cabling.

1

!

Warning! Refer to the RJ45 Warning for compatibility

information.
The Symetrix ARC-PSe provides serial control and power

distribution over standard CAT5/6 cable for systems with more

than 4 ARCs, or, when any number of ARCs are located long

distances from a Integrator Series, Jupiter or SymNet DSP unit.

Port Settings: 38.4 kbaud, 8 data bits, 1 stop bit, no parity, no
flow control.

The following table provides at-a-glance cable length limitations

based on DC power (the table is not relevant if only RS-485 is

distributed) and assumes 24 gauge CAT5/6 cabling. The lengths

for multiple ARCs on a single chain assume equal distance for

each cable segment between ARCs. Table is intended for quick

reference only. For more detailed configuration scenarios

Special note: for multiple ARCs on single chain, the listed value

is assumed to be the cable length between each device. For

example, a value of 600’ means 600’ between the DSP unit and

the first ARC, 600’ between the first and second ARCs, etc. The

total cable length will be the listed segment length multiplied by the

number of ARCs on the chain.

number of ARCs

on chain

ARC-2e/ARC-2i ARC-K1e ARC-SW4e ARC-SWK ARC-XLR ARC-MIC

1

1000'

3250'

3250'

1800'

3250'

3250'

2

370'

1200'

1200'

600'

1200'

1200'

3

190'

600'

600'

325'

600'

600'

4

115'

350'

350'

200'

360'

360'

CABLE SEGMENT LENGTH LIMITATIONS FOR ARC POWER OVER CAT-5/6 CABLE

ARC TYPE

ARC-EXK ARC-EX4e

1

4

2

3

1

3

2

3

2

3

ARC-SWK

ARC-MIC

ARC-XLR

MAXIMUM NUMBER OF ARC EXPANSIONS UNITS POSSIBLE PER

MODULAR ARC BASE UNIT

MODULAR ARC BASE UNIT

ARC-K1e

ARC-SW4e

Declaration of Conformity

We,

Symetrix Incorporated, 6408 216th St. SW,

Mountlake Terrace, Washington, USA, declare under our

sole responsibility that the product:

Jupiter•4, Jupiter•8, and Jupiter•12

to which this declaration relates, is in conformity with the

following standards:

IEC 60065,

EN 55103-1, EN 55103-2, FCC Part 15, RoHS

The technical construction file is maintained at:

Symetrix, Inc.

6408 216th St. SW

Mountlake Terrace, WA, 98043 USA

The authorized representative located within the European

Community is:

World Marketing Associates

P.O. Box 100

St. Austell, Cornwall, PL26 6YU, U.K.

Date of issue: April 26, 2010

Place of issue: Mountlake Terrace, Washington, USA

Authorized signature:

Dane Butcher, President, Symetrix Incorporated.

ARC Distance Table

1
2
3
4
5
6
7
8

1
2
3
4
5
6
7
8

1 • AUDIO (+)
2 • AUDIO (-)
3 • COMMON GROUND
4 • RS-485 DATA (A)
5 • RS-485 DATA (B)
6 • COMMON GROUND
7 • POWER (+V)
8 • POWER (+V)

Note:

The ARC Audio line may be grounded at the

Symetrix rack-mount device and the ARC wall panel
to provide additional distance.

ARC PORT PINOUT

8

7

6

5

4

3

2

1

Pair 1

Pair 3

Pair 4

Pair 2