THE INSTALLATION SPACE
Free-Standing – Use canopy top Built-In – Remove canopy top
(if needed)
Choose the location:
• This product has been designed as a free-standing unit;
however, if desired, it may also be built-in.
• These products may be closed in on the top and
three sides as long as the front is unobstructed for
air circulation and proper access to the door.
• Do not operate these products where the temperature
will go below 45°F (7°C) or above 120°F (49°C).
• Unit must be installed on a structurally sound and
level surface strong enough to support a fully loaded
refrigerator, or approx. 250 lbs.
• The Outdoor/Indoor Refrigerator can be used
free-standing.
*For a standard installation: The product must be installed
so that the stainless steel front will project 1-7/8" forward
of adjacent cabinets. This position will allow a full door swing
and prevent interference with adjacent cabinetry.
The opening between cabinets must be 23-3/4" minimum.
**For a flush installation: Install a 1/2"-wide filler strip on
the hinge side. The filler strip will act as a spacer between
the door case and adjacent cabinets and will prevent
interference with the cabinet door swing. Recess the filler
strip 1-7/8" back from the front face of the refrigerator, or
even with the front edge of the product case (behind the
gasket). The width of the opening must be 24-1/2" (including
the 1/2" filler strip).
Additional Specifications
• A 120 volt 60Hz., 15 or 20 amp power supply is
required. An individual properly grounded branch circuit
or circuit breaker is recommended. Install a properly
grounded 3-prong electrical receptacle recessed into
the back wall as shown. Electrical must be located
on rear wall as shown.
THIS PRODUCT MUST BE
CONNECTED TO A POWER SOURCE WITH GROUND
FAULT CIRCUIT INTERRUPTER (GFCI) PROTECTION
WHEN INSTALLED IN AN OUTDOOR LOCATION. LOCAL
CODES MAY REQUIRE A SEPARATE CIRCUIT.
THE INSTALLATION SPACE (cont.)
These products will fit flush
to adjacent cabinets when
installed with a 1/2" filler panel
or cleat. The filler panel should
be recessed or set back behind
the door and even with the front
edge of the product case.
In a standard installation,
the product will project 1-7/8"
forward of adjacent cabinets.
Flush
Installation
CABINET
CABINET
CABINET
CABINET
1-7/8"
1/2"
120°
120°
110°
110°
Filler panel or cleat
to be set back even
with front of case.
Front edge of product case
Front face
Front face
Front edge of product case
Standard
Installation
NOTE:
Handle and
handle standoff
depth is 2-7/8"