beautypg.com

Flow check (duct condition test) – LG DLG2602R User Manual

Page 26

background image

Your dryer features FlowSense

TM

, an innovative

sensing system that automatically detects blockages

and restrictions in dryer ductwork. Keeping ductwork

clean of lint buildup and free of restrictions allows

clothes to dry faster and reduces energy use.
NOTE: When the dryer is first installed, this test

should be performed to alert you to any existing

problems with the exhaust duct in your home.

However, since the test performed during normal

operation provides more accurate information on

the condition of the exhaust duct than does the

installation test, the number of bars displayed during

the two tests may not be the same.

To activate the fl ow check (Duct condition test) :

NOTE: Dryer heating test must be performed before

proceeding. Then perform the duct condition test

below:

Press and hold the DAMP DRY BEEP and

TEMP. CONTROL buttons at the same time.

While holding these buttons, press POWER

ON/OFF.

The dryer will show lnS in the number display

to indicate that it is in duct condition testing

mode.

FLOW CHECK (DUCT CONDITION TEST)

Correct Venting

Restricted or Blocked Airflow

Avoid long runs or runs with multiple elbows

or bends.

Check for blockages and lint buildup.

Make sure the ductwork is not crushed

or restricted.

1

2

3

Press START/PAUSE. The dryer

will run for approximately 2

minutes to test for blockages

or restrictions to air fl ow in the

ductwork.

If FLOW SENSE indicator light is on,

the dryer ductwork has a blockage that

needs to be removed immediately.

IMPORTANT: Do NOT interrrupt the test cycle!

26

3828EL3010X_en(GDP)_090410.indd 26

2009.4.10 4:49:56 PM

This manual is related to the following products: