beautypg.com

English, Temperature limiting, Removing the front grille – LG LP155CED1 User Manual

Page 17: Additional controls

background image

Control Locations

Owner’s Manual 17

ENGLISH

• TEMPERATURE LIMITING

Temperature Limiting can save money by limiting the lowest temperature for cooling and the highest
temperature for heating. The temperature limiting is controlled by dip switch #1 - #3.
This temperature limiting is not available with the Remote Wall Thermostat.

OFF

OFF

OFF

54°F (12.2°C) 86°F (30.0°C) 54°F (12.2°C)

86°F (30.0°C)

ON

OFF

OFF

56°F (13.3°C) 86°F (30.0°C) 54°F (12.2°C)

84°F (28.9°C)

OFF

ON

OFF

58°F (14.4°C) 86°F (30.0°C) 54°F (12.2°C)

82°F (27.8°C)

ON

ON

OFF

60°F (15.5°C) 86°F (30.0°C) 54°F (12.2°C)

80°F (26.7°C)

OFF

OFF

ON

62°F (16.6°C) 86°F (30.0°C) 54°F (12.2°C)

78°F (25.5°C)

ON

OFF

ON

64°F (17.7°C) 86°F (30.0°C) 54°F (12.2°C)

76°F (24.4°C)

OFF

ON

ON

66°F (18.9°C) 86°F (30.0°C) 54°F (12.2°C)

74°F (23.3°C)

ON

ON

ON

68°F (20.0°C) 86°F (30.0°C) 54°F (12.2°C)

72°F (22.2°C)

Temperature Temperature Temperature

Limit #1

Limit #2

Limit #3

Lowest Temp. Highest Temp. Lowest Temp. Highest Temp.

Cooling Operation

Heating Operation

• REMOVING THE FRONT GRILLE

Additional controls are available after removing the
front grille and option cover of control box.
To remove the front grille, pull out the bottom of front
grille and then lift up.

To replace the front grille, place the tabs over the top
of the unit and push the bottom of front grille until the
clips snap into place.

• ADDITIONAL CONTROLS

The additional controls are located behind the option cover of control box. The standard settings will be in
the OFF position. The authorized service man has to check switches and ensure the switches are in the
desired position.

LOCAL

1

OFF

2

OFF

3

OFF

4

OFF

5

LOCAL

1

OFF

2

OFF

3

OFF

4

OFF

5

ON

ON

REMOTE

OFF

ON

ON

ON

Remote/Local
Energy Saver
Temperature Limit#1
Temperature Limit#2
Temperature Limit#3

LOCAL

LOCAL

1

OFF

OFF

2

OFF

OFF

3

OFF

OFF

4

OFF

OFF

5

LOCAL

1

OFF

2

OFF

3

OFF

4

OFF

5

LOCAL

LOCAL

1

OFF

OFF

2

OFF

OFF

3

OFF

OFF

4

OFF

OFF

5

LOCAL

1

OFF

2

OFF

3

OFF

4

OFF

5