Installation, Information, Motor terminal box – NORD Drivesystems TI 18552090 User Manual
Page 2
Level adapter PCB – HTL-RS422
2
TI 18522090 - 4813
Signal delay
Tests
Rising flank 250 ns
EN61000-4-2 ESD 4 kV contact discharge
Falling flank 750 ns
8 kV air discharge
Protection
EN61000-4-4 Burst 1 kV signal cables
Power supply Reverse polarity protected
2 kV power supply
Outputs Short-circuit protected
EN61000-4-5 Surge 1 kV signal cables
Overtemperature Switch-off at 150°C
2 kV power supply
Pos : 3 /T ec hnis che Inf or mationen/ Zubehör/Pl ati ne_Pegel wandl er_C ontel ectg eber/Mont age [ Plati ne Pegel anpass ung ] @ 4\mod_1380536273119_388. doc x @ 100204 @ 5 @ 1
Installation
Installation location
In motor terminal box
Mounting
Double screw fastening with installation kit (Part No.: 18552160)
Installation kit consisting of:
2 x
M4 screws
2 x
Toothed washers
6 x
Plastic washers
Illustration of installation
kit
Tools
Slot-head screwdriver 0.6 x 3.5
Information
Motor terminal box
The PCB is installed in an adequately dimensioned motor terminal box. Installation in a one-piece terminal box
(EKK) is not possible.
1.
Insert the M4 screws (1) with toothed washers (2) from above into
the holes provided (3).
2.
Put 3 plastic washers (1) onto each screw from the underside.
3.
Screw the PCB into the terminal box.
Pos : 4 /T ec hnis che Inf or mationen/ Zubehör/Pl ati ne_Pegel wandl er_C ontel ectg eber/Ansc hl üss e [ Platine Pegel anpass ung HT L ... ] @ 4\ mod_1380537501717_388.doc x @ 100255 @ 5 @ 1