beautypg.com

Installation, Information, Motor terminal box – NORD Drivesystems TI 18552090 User Manual

Page 2

background image

Level adapter PCB – HTL-RS422

2

TI 18522090 - 4813

Signal delay

Tests

Rising flank 250 ns

EN61000-4-2 ESD 4 kV contact discharge

Falling flank 750 ns

8 kV air discharge

Protection

EN61000-4-4 Burst 1 kV signal cables

Power supply Reverse polarity protected

2 kV power supply

Outputs Short-circuit protected

EN61000-4-5 Surge 1 kV signal cables

Overtemperature Switch-off at 150°C

2 kV power supply

Pos : 3 /T ec hnis che Inf or mationen/ Zubehör/Pl ati ne_Pegel wandl er_C ontel ectg eber/Mont age [ Plati ne Pegel anpass ung ] @ 4\mod_1380536273119_388. doc x @ 100204 @ 5 @ 1

Installation

Installation location

In motor terminal box

Mounting

Double screw fastening with installation kit (Part No.: 18552160)

Installation kit consisting of:

2 x

M4 screws

2 x

Toothed washers

6 x

Plastic washers

Illustration of installation
kit

Tools

Slot-head screwdriver 0.6 x 3.5

Information

Motor terminal box

The PCB is installed in an adequately dimensioned motor terminal box. Installation in a one-piece terminal box
(EKK) is not possible.

1.

Insert the M4 screws (1) with toothed washers (2) from above into
the holes provided (3).

2.

Put 3 plastic washers (1) onto each screw from the underside.

3.

Screw the PCB into the terminal box.