Technical specification – Noby UK Noby-65 User Manual
Page 7
Noby-65 Installation Manual & Operating Instructions (Rev.1)
Page 7 of 12
TECHNICAL SPECIFICATION
Power Supply Unit
Value Unit
Comments
Mains Supply Voltage
230 +10% -6%
volts AC
Mains Supply Frequency
50 / 60
Hz
Mains Power Rating
30
VA
Nominal Battery Voltage
12
volts
Regulated PSU charger voltage
13.6
volts
Regulated PSU charger current:
• 20 minute rating
• continuous rating
2.0
1.5
A
A
Fused Outputs:
F1
30VAC Transformer Secondary
F2
Auxillary 12v Supply
F3 Battery
+’ve
F4
Fire Alarm Outputs
F5
Intruder Alarm Output
F6
Water Alarm & Internal Buzzer
2.0
500
3.0
1.0
1.0
1.0
A
mA
A
A
A
A
T2A
20mm Quick Blow
F500mA
20mm Quick Blow
T3A
20mm Quick Blow
F1A
20mm Quick Blow
F1A
20mm Quick Blow
F1A
20mm Quick Blow
Standby Battery Current
70
mA
9 EOL resistors fitted
Low Voltage Monitor
10.0
volts
Battery Condition Test
Yes
10s load test every 12hrs
Detection Circuits
Value Unit
Comments
No. Detection Circuits:
7
Zone-1, Zone-2, Exit/Entry,
Duress/Panic, Fire, Water,
Sabotage (Anti-Tamper).
End Of Line (EOL) Resistor
10,000
ohms
Open Circuit Monitoring
R > 17,000
ohms
No. Detectors Per Fire Zone
10
based on 100uA per detector
Fire Circuit Detection Threshold
R< 3000
ohms
Alarm Output Circuits
Value Unit
Comments
Intruder Alarm Output
SPDT Relay
12v centre contact, fuse F5
24Hr Fire Alarm Output
0 –> 12
volts
open-collector pnp transistor, fuse F4
12Hr Fire Alarm Output
0 –> 12
volts
open-collector pnp transistor, fuse F4
Water Alarm Output
12 –> 0
volts
open-collector npn transistor, fuse F6
Internal Buzzer Output
12 –> 0
volts
open-collector npn transistor, fuse F6
Signal Outputs
Value Unit
Comments
Duress / Panic Signal
10
mA
0v --> 12volt, +’ve going signal
SW+ Signal (panel SET signal)
10
mA
0v --> 12volt, +’ve going signal
Cabinet
Value Unit
Comments
Dimensions (width x height x depth)
368 x 275 x 75
mm
1.2mm powder coated steel
Shipping Weight:
4.5
Kg