Hoyles Boxed Mains Rated Relay Module User Manual
Installation instructions, Hoyles electronic developments ltd, S361-mb mains relay
Installation Instructions
S361-MB Mains Relay
This relay is designed for switching a 240vac mains load of up to 5A operated by a 12vdc input. The 12vdc relay coil is rated at 35mA. The
relay is contained within a white plastic single gang enclosure.
To operate the relay, apply 12vdc to the + and - terminals. The spring provided for the tamper switch needs to be pushed on to the tamper
switch before finally fixing the face plate in place.
If the relay is to be used for mains switching, then the mains wiring should be installed as specified by the current edition of the IEE wiring
regulations or as specified by the relevant country specific wiring regulations.
The enclosure is tampered and contains a relay with double pole change over contacts rated 5A at 240vac or 12/24vdc. The relay coil
requires 12vdc to operate. An LED is also provided which illuminates when the relay is energised. The tamper switch is normally closed
and opens when the face plate is removed from the wall. An earth terminal is also provided for convenient termination of an in coming
mains cable. As the enclosures are all plastic, no earth connection is required.
The enclosure is supplied un-labelled. The decal (included) has a clear window 10mm x 46mm. The area under the decal is 12mm wide to
take standard labelling machine tape. The window is free from adhesive, nevertheless, it is wise to maintain cleanliness and avoid fingerprints on
the inside of the window. If a labelling machine is not available a paper label can be used and examples are given below complete with cutting
and folding lines. If the text you require is not shown here then it is a fairly simple matter to make one with a word processing or graphics
programme. The dimensions here are given to help you.
65.0
49.0
1
2
.0
F
o
ld
F
o
ld
F
o
ld
F
o
ld
F
o
ld
F
o
ld
F
o
ld
F
o
ld
F
o
ld
F
o
ld
F
o
ld
F
o
ld
F
o
ld
F
o
ld
F
o
ld
F
o
ld
F
o
ld
F
o
ld
F
o
ld
F
o
ld
F
o
ld
F
o
ld
F
o
ld
F
o
ld
F
o
ld
F
o
ld
Extent of Clear Window
Text in this 10mm x 46mm area
Mains Relay
Fire Relay
Shutter Relay
Lighting Relay
Alarm Relay
Lock Relay
Mains Relay
Terminals
Fire Alarm
Relay
Heater Control
Relay
Lighting Relay
Terminals
Alarm Relay
Terminals
Lock Relay
Terminals
TE
XT
Fo
ld
Before applying decal
fold paper label
and insert through slots
Ensure all surfaces are clean
and free from dust etc..
DWG: 60140 iss1 Mar 12
T. 01744 886600 F. 01744 886607 E. [email protected] W. www.hoyles.com
Hoyles Electronic Developments Ltd
Tamper
Switch
T
T
T
T
C
O
M
N
O
N
C
C
O
M
N
O
N
C
+
-
Tamper switch
terminals
Contact rating
5A @ 250vac
5A @ 12/24vdc
Apply 12vdc
to switch relay
LED illuminates when
relay is switched
Tampered relay enclosure
Earth terminal for termination
of incoming cable. Connection
is not required.
Terminals will accept cable
2
sizes up to 2.5mm , however
2
1mm is recommended