SPECIFICATIONS
Wetted Materials:
304 SS.
Lens: Scratch resistant glass.
Accuracy: ±1%.
Ambient Operating Temperature: 15 to 300˚F (-10 to 150˚C).
Dial Size: 3˝.
Connection: 1/2˝ NPT.
Resolution: 2°.
Weight: 7.4 oz (210 g).

The Series BTM3 Maximum/Minimum Bimetal Thermometer
accurately measures the current temperature along with the
maximum or minimum temperatures. The adjustment knob is
used to reset the minimum or maximum temperature to the cur-
rent reading. Series BTM3 thermometers are conveniently
available in multiple temperature ranges and stem lengths rang-
ing from 2-1/2 to 12 inches. These heavy duty back-connected
thermometers are ideal for any industrial application such as
boilers, ovens, or refrigerated cabinets.

STEM LENGTH

1/2 NPT

1

[25.4]

13/16

[20.64 ]

DIAL

SIZE

Ш3-9/32

[Ш83.34]

T-14:Layout 1 3/25/09 8:52 AM Page 1