Ordering information pressure ranges, Pressure psi, Pressure code v ented – AST AST4600 Datasheet User Manual
Page 2: Pressure code factory sealed, Wiring
TM
www.astsensors.com
© 2014 American Sensor Technologies Inc. AST4600 01/30/2014.
All specifications subject to change without notice.
Ordering Information
Pressure Ranges
++
2.5 and 7.5 PSI units must be ordered in inches of H
2
O
Pressure PSI
0-1
Pressure Code V
ented
G
0001
Pressure PSI
0-100
Pressure Code Factory Sealed
0
0100
0-2.5
++
G
0069
0-200
0
0200
0-5
G
0005
0-500
0
0500
0-7.5
++
G
0208
0-1,000
0
1000
0-10
G
0010
0-1,500
0
1500
0-15
G
0015
0-2,500
0
2500
0-25
G
0025
0-3,000
0
3000
0-50
G
0050
0-5,000
0
5000
0-100
G
0100
0-7,500
0
7500
0-200
G
0200
0-10,000
1
0000
0-500
G
0500
0-15,000
1
5000
0-1,000
G
1000
0-20,000
2
0000
Output
Red
Black
White
Green
Voltage
+V Supply
-V Supply
Output
Case Ground
4-20mA
+V Supply
-V Supply
Not Used
Case Ground
For U.S. installations, sensor case ground (green wire) must be
bonded to ground according to Article 501 & 505 of the NEC.
Wiring
Options
000= No Options
Process Connection*
A= 1/4" NPT Male (up to 10,000 PSI)
I= 1/4" NPT Female (up to 15,000 PSI)
P= 1/2" NPT Male (up to 15,000 PSI)
W= F250C Female Autoclave (10,000 to 20,000 PSI)
* for other ports contact factory, "W" not available in 316L
Pressure Unit
B= Bar
K= kg/cm
2
P= PSI
Wetted Material
+
0= 17-4PH 1= 316L 2= Inconel 718 4= Hastelloy C276
+
Consult factory on availability of Inconel 718 and Hastelloy C276
Series Type
Insert Pressure Code
AST4600
A
0000
P
4
1
000
T
1
Pressure Range
G= Gauge Pressure**
V= Gauge Pressure (Vacuum Calibrated)**
0= Sealed Gauge up to 9,999 PSI
1= Sealed Gauge up 10,000 to 19,999 PSI
2= Sealed Gauge 20,000 PSI
** Not suitable for Class II
Electrical
T= 2ft. 18 AWG wires
U= 4ft. 18 AWG wires W= 2 Meter 18 AWG wires
Outputs
3= 1-5V 4= 4-20mA (2 wire loop powered) 6= 1-6V
-Z
Approval
-Z= Add “-Z” for CRN Registered to ANSI/ASME B31.3. Contact factory for material, pressure, and process connection options.