beautypg.com

Control panel, Troubleshooting (cont.) – SoleusAir SG-DEH-70E-2 User Manual

Page 6

background image

6

CONTROL PANEL

(1)

(2)

(3)

(12) (13)

(10) (11)

(6)

(8)

(7)

(5)

(4)

(9)

POWER ON/OFF (1)

Once the unit is plugged in, the POWER INDICA-
TOR (10) will light. Pressing the POWER button

once will turn the unit ON and illuminate the digi-
tal display (9). The fan will operate for 3 minutes

to draw air through the dehumidifier to properly
sense relative humidity. The display will show the

humidity level of the room in 5% increments,
down to a minimum of 25%. Pressing the Power

button again will turn the display OFF and the
unit will cease operating.

HUMIDITY LEVEL (2/3)
The humidity level can be set in 5% increments in

a range from 35% to 80%. The humidity setting
is shown in the digital display. When the humid-

ity level of the room reaches the set level, the
compressor will stop, but the fan will continue

operating for 3 minutes. To set the unit to continu-
ous operation,

press the "-"

arrow button until

the display shows 35%. Press again and the dis-
play will show CO. The Continuous indicator (13)

will light up on the control panel. To leave con-

tinuous operation, press the
To check the current humidity setting, press the

FAN SPEED (5)

Press Fan Speed to toggle between Low, Med,
and High fan speeds. Speed will be shown in FAN

SPEED INDICATOR (8)
BUCKET FULL INDICATOR (11)

When the collection bucket is full, the BUCKET
FULL indicator (11) will light up and you will hear

an audible alarm. The audible alarm will last up
to ten seconds The dehumidifier will not run until

the bucket is removed, emptied and replaced.

DELAY START (4)

Unit can be programmed to turn on at a desired
delay time by pressing the Timer (4) key. When

the unit is powered OFF, press the timer key once
for 2-hour delay start. The 2 Hrs (7) timer indica-

tor will light up when the timer key is pressed.
Press the timer key once more for a 4-hour delay

start. The 4 Hrs (7) timer indicator will now light
up. Press the timer key a third time to clear the

timer setting. No timer indicators will light up
when the timer setting is cleared.

AUTO SHUT-OFF (4)
Unit can be programmed to turn off at a desired

time by pressing the Timer (4) key. When the unit
is powered ON, press the timer key once for 2-

hour automatic shut-off. The 2 Hrs (7) timer indi-
cator will light up when the timer key is pressed.

Press the timer key once more for a 4-hour auto-
matic shut-off. The 4 Hrs (7) timer indicator will

now light up. Press the timer key a third time to
clear the timer setting. No timer indicators will

light up when the timer setting is cleared.


FILTER RESET (12)

The FILTER RESET indicator (12) will light up when
the filter needs cleaning. Remove the filter and

clean accordingly. Replace the filter when fin-
ished and press and hold the FILTER (6) key up to

5 seconds to reset the filter indicator.
IMPORTANT:

Once the set humidity level is reached, the

compressor will shut off. The fan will con-
tinue to run for up to 3 minutes.

Anytime the compressor stops running for

any reason, it will not restart for a minimum
of 3 minutes. This is a design feature to pro-

tect the compressor from damage.

15

Problem Possible

Causes

Solutions

The area to be dehumidified

is too large.

The capacity of your dehumidifier may

not be adequate for the room size.

Doors and windows are

open.

Close all doors and windows to the out-

side.

Frost appears on the

coils

The dehumidifier has recently

been turned on or the room

temperature is below 41°F.

This is normal. Frost will usually disappear

within 60 minutes.

Controls cannot be set Bucket is full or it has been

removed.

Empty bucket and install properly in unit.

Fan Noise

Air is moving through the

unit.

This is normal.

Water on the floor

Hose connection may be

loose.

Check the hose connection. See the Drain-

age Section

Hose is attached but not

draining into a drain

Disconnect the hose if using the bucket or

place the hose near a drain.

Unit is discharging
warm air

Normal:

Compressor and electric motor

discharge nominal heat.

Water does not

drain through the
dehumidifier drain
hose

Check the drainage joint and

hose on the

dehumidi-

fier. Is it installed correctly?

Check the drain hose for

kinks or obstructions.

Re-install the dehumidifier drainage joint

and hose according to the manual.


Flatten the hose or remove blockage.

Water does not
drain through the

pump drain hose

Check the pump drain hose

on the pump. Is it installed
correctly?

Check the pump drain hose

for kinks or

obstruc- tions.

Re-install the pump drain hose according

to the manual.

Flatten the hose or remove blockage.

Dehumidifier runs too
much

TROUBLESHOOTING (Cont.)

"+" (3) arrow.

"+" and "-" arrow. The display will show and

set 5% above or below the current settings.

(2)