52

Meter roller wont turn

No fan speed

Outer opener sections engage when turning

Meter gate alarms going off

Probable Cause

Solution

No hydraulic pressure.

Engage hydraulic circuit (wing down).

Product control switch is
off.

Turn product control switch to auto.

Roller is jammed.

Remove roller from meter body and remove
obstruction from meter.

Check air cart node.

Check lights on front of node.

Check meter settings.

Make sure that the meter cal and cal weight is
entered correctly.

Probable Cause

Solution

Fan sensor out of
alignment.

Check and re-align sensor if necessary.

Fan cal is incorrect.

Set fan cal to 2

No hydraulic pressure.
Diverter block is set to the
auger/conveyor position.

Set diverter to the fan position

Speed settings set
incorrectly.

Probable Cause

Solution

No field boundary 
recorded.

Create a field boundary.

Aggressiveness is on.

Turn aggressiveness off.

Improper look aheads.

Adjust look ahead time.

Diverter block is set to the
auger/conveyor position.

Set diverter to the fan position.

Probable Cause

Solution

Proximity sensors on gates
misaligned.

Align proximity sensors.

Gates not functioning.

See “gates will not open/close”.

Proximity sensor damaged. Replace proximity sensor.

53

7.3 Nodes on SCT

®

Implements

Nodes present on SCT

®

implements:

Switchbox Node
Drill Node
SCT

®

Node 1

SCT

®

Node 2

3 Product Node
Single Product Node (Optional)
Seed Blockage Node (Optional)

Switchbox Node: Controls on/off/auto/SCT

®

functions

Drill Node: Controls toolbar opener sections 1-8 and packing pressure PWM
signal
Reads: Packing pressure transducer

SCT

®

Node 1: Controls function of meter gate sections 1-16 (Meter 1 & 2)

Reads: proximity sensors 1-16

SCT

®

Node 2: Controls function of meter gate sections 17-24 (Meter 3)

Reads: Proximity sensors 17-24

3 Product Node: Controls speed of hydraulic drive motors 1-3
Reads: Ultrasonic Bin level sensors.
Fan rpm sensors
Hydraulic drive motor encoder

Single Product Node(s) (Optional): Present on Liquid & NH

3

SCT

®

Sys-

tems, controls all functions pertaining to the Liquid or NH

3

hardware ie; Boom

valves, control valves, flow meters, pressure transducers.

Seed Blockage Node (Optional): Reads the blockage sensors and reports
when runs are clear, dirty or blocked