Hired-Hand PowerTrak: Limit Switch Retaining Bracket User Manual
Limit switch retaining bracket, Powertrak
HIRED-HAND, INC.
·
1733 Co Rd 68
·
Bremen, AL 35033
·
Phone 1-800-642-0123
·
Fax 205-287-2000
Limit Switch Retaining Bracket
PowerTrak
tm
Part No. 4801-0052
Tools Required
11/32” Socket
7/16” Socket
7/16” Wrench
Screwdriver
1/4” Nut Driver
1/8” Allen Wrench
Directions
1. Disconnect electrical power to the PowerTrak.
2. Open and remove the side swinging door.
3. Disconnect both quick connects at the bottom of the machine. The large connector is for the limit
switches, and the small connector is for the motor.
4. Remove the four bolts that hold the bottom plate in place.
5. Slide out the bottom assembly.
6. Remove the four bolts holding the limit switch assembly to the cabinet.
7. Loosen set-screw holding limit switch cam in place.
8. Slide out the limit switch assembly. When removing this part, notice the alignment of the switches.
You will need to install the new assembly in this same arrangement.
9. Insert the cam between the limit switches as shown below.
10. Replace the 1/4”X1/2” set-screw with the new 1/4”X3/4” set-screw. Do not fully tighten set-screw.
11. Carefully remove the four bolts holding the limit switches to their mounting plate.
12. Place new bracket cover over the limit switches as shown above. Replace the four bolts removed in
step 10 above. Be sure not to switch positions with the limit switches.
13. Slide new limit switch assembly onto control rod.
14. Lock down limit switch assembly using the original bolts.