Nematron iPC-Fanless Series with N2800 CPU User Manual
Page 9
________________________________________________________________________________________
Document No. DOC-IPC-003,
User Manual iPC-Series & nPC300, Rev B Rel. 12-2013
Page 9 of 24
ELECTRICAL
AC Input Voltage
100
– 240 VAC, 50/60 Hz
AC Input Current
1.0 A Maximum
DC Input Voltage (Optional)
18
– 36 VDC
DC Input Current (Optional)
6.0 A Max @ 24VDC
Input Power
nPC300
– 60 W Typical* (40 W for N2800 Option)
iPC1200 - 70 W Typical* (50 W for N2800 Option)
iPC1700
– 80 W Typical* (60 W for N2800 Option)
iPC1700
– 85 W Typical* (65 W for N2800 Option)
iPC1900
– 90 W Typical* (70 W for N2800 Option)
* Typical Power is measured without any additional I/O or expansion options. Any additional I/O installed
during application can increase this value.
ENVIROMENTAL
Operating Temperature
0
C to 55
C (50
C for Enclosed
Options
Non-Operating Temperature
-20
C to 60
C
Operating & Non-Operating Humidity
20% to 80% RH, non-condensing
Operating Shock*
15g peak acceleration, 11msec
Non-Operating Shock
30g peak acceleration 11msec
Operating Vibration (5-2000 Hz)
1
0.006” peak to peak displacement,
1g maximum acceleration
Non-Operating Vibration (5-2000 Hz)
1
Operating Altitude
2
Sea level
– 10,000 feet
Non-Operating Altitude
2
Sea level
– 40,000 feet
1 Shock and Vibration specifications are established using Solid State drives and non-rotating media.
2 Altitude Specification is established by using all internal component specifications.