ELECTRICAL

AC Input Voltage

100

– 240 VAC, 50/60 Hz

AC Input Current

1.0 A Maximum

DC Input Voltage (Optional)

18

– 36 VDC

DC Input Current (Optional)

6.0 A Max @ 24VDC

Input Power

nPC300

– 60 W Typical* (40 W for N2800 Option)

iPC1200 - 70 W Typical* (50 W for N2800 Option)

iPC1700

– 80 W Typical* (60 W for N2800 Option)

iPC1700

– 85 W Typical* (65 W for N2800 Option)

iPC1900

– 90 W Typical* (70 W for N2800 Option)

* Typical Power is measured without any additional I/O or expansion options. Any additional I/O installed
during application can increase this value.

ENVIROMENTAL

Operating Temperature

0

C to 55

C (50

C for Enclosed

Options

Non-Operating Temperature

-20

C to 60

C

Operating & Non-Operating Humidity

20% to 80% RH, non-condensing

Operating Shock*

15g peak acceleration, 11msec

Non-Operating Shock

30g peak acceleration 11msec

Operating Vibration (5-2000 Hz)

1

0.006” peak to peak displacement,

1g maximum acceleration

Non-Operating Vibration (5-2000 Hz)

1

Operating Altitude

2

Sea level

– 10,000 feet

Non-Operating Altitude

2

Sea level

– 40,000 feet


1 Shock and Vibration specifications are established using Solid State drives and non-rotating media.
2 Altitude Specification is established by using all internal component specifications.














This manual is related to the following products: