9.2 Direction of rotation
The PTO rotation is indicated by an arrow located on the casing near the drive shaft. From a position facing the pump
head, the rotation direction will be as in fig. 5.
The version may be changed only by trained and authorized personnel by carefully
following the instructions in the repair manual.
9.3 Version Change and Reducer Positioning
A right version pump is defined when: observing the pump from the head side, the PTO shank of the pump shaft is on
the right side.
A left version pump is defined when: observing the pump from the head side, the PTO shank is on the left side.
See fig. 5.
1. Separate the manifold from the power end (crankcase) as indicated in Chapter 2 in point 2.2.1 of the Repair
Manual.
2. Turn the power end (crankcase) 180
o
and reposition the rear casing cover in such a way that the oil dipstick is
turned upward. Reposition the lifting bracket and relative hole closing plugs in the upper part of the casing. Finally,
properly reposition the specification label in its housing on the casing.
Make sure that the lower inspection cover draining holes are open.
3. Reassemble the manifold with the power end (crankcase) as indicated in Chapter 2 in point 2.2.5 of the Repair
Manual.
Ref 300941 Rev.A