beautypg.com

Htck4050s, General pump, Screw tightening calibration – General Pump HTCK4050S User Manual

Page 16

background image

GENERAL PUMP

A member of the Interpump Group

HTCK4050S

Page 16

Ref 300934 Rev.A

09-13

3. SCREW TIGHTENING CALIBRATION

Description

Exploded Drawing

Position #

Tightening Torque

Cover fixing screw

9

7.4 ft.lbs. (10 Nm)

Piston fixing screw

29

14.8 ft.lbs (20 Nm)

Connecting rod cap fixing screw

16

22.1 ft.lbs (30 Nm)*

Head fixing screw

41

59.0 ft.lbs (80 Nm)**

Valve cover fixing screws

42

88.5 ft.lbs (120 Nm)***

Lifting bracket fixing screw

59

29.5 ft.lbs (40 Nm)

Oil discharge plug

11

29.5 ft.lbs (40 Nm)

Outlet conduit plug

54

29.5 ft.lbs (40 Nm)

G1” outlet plug

26

110.6 ft.lbs (150 Nm)

G1-1/2” suction plug

28

110.6 ft.lbs (150 Nm)

Type “A” flange fixing screw

66

29.5 ft.lbs (40 Nm)

* The connecting rod cap fixing screws must be tightened

respecting the stages indicated on page 7

** The head fixing screws must be tightened with a

torque wrench, lubricating the underhead, respecting the order in fig. 25

*** The valve cover fixing screws must be tightened with a torque wrench,

lubricating the underhead, respecting the order in fig. 25