Htck4050s, General pump, Screw tightening calibration – General Pump HTCK4050S User Manual
Page 16
GENERAL PUMP
A member of the Interpump Group
HTCK4050S
Page 16
Ref 300934 Rev.A
09-13
3. SCREW TIGHTENING CALIBRATION
Description
Exploded Drawing
Position #
Tightening Torque
Cover fixing screw
9
7.4 ft.lbs. (10 Nm)
Piston fixing screw
29
14.8 ft.lbs (20 Nm)
Connecting rod cap fixing screw
16
22.1 ft.lbs (30 Nm)*
Head fixing screw
41
59.0 ft.lbs (80 Nm)**
Valve cover fixing screws
42
88.5 ft.lbs (120 Nm)***
Lifting bracket fixing screw
59
29.5 ft.lbs (40 Nm)
Oil discharge plug
11
29.5 ft.lbs (40 Nm)
Outlet conduit plug
54
29.5 ft.lbs (40 Nm)
G1” outlet plug
26
110.6 ft.lbs (150 Nm)
G1-1/2” suction plug
28
110.6 ft.lbs (150 Nm)
Type “A” flange fixing screw
66
29.5 ft.lbs (40 Nm)
* The connecting rod cap fixing screws must be tightened
respecting the stages indicated on page 7
** The head fixing screws must be tightened with a
torque wrench, lubricating the underhead, respecting the order in fig. 25
*** The valve cover fixing screws must be tightened with a torque wrench,
lubricating the underhead, respecting the order in fig. 25