INTELLINET NETWORK 351898 Multifunction Cable Tester User Manual User Manual
Page 2
2
To Test USOC 4/6/8 Modular Cable:
1. Connect one end of the cable to the master tester and the other
end to the remote terminator. (You can connect both ends to the
master unit if you’re not doing a remote test.)
2. Press the Power button to the on position. The Power led will
flash to indicate the device is powered properly.
3. As soon as the test cable is inserted, the LEDs on the remove
terminator will start to scan one by one.
4. If the test cable is okay, the corresponding pair of leds will light
green.
5. If the corresponding pair of leds light red, the cable has been
wired in reverse.
6. If the LEDs light green first and then red (mixed) or remain unlit,
the cable is bad.
NOTE: Make sure a 9-volt alkaline battery has been installed in the
battery compartment.
CauTiON: Don’t connect the cable tester to live circuits as it may be
damaged by high voltage.