INSTALLATION

• Best results are achieved when the unit is installed where the HVAC

air temperature is most constant. Therefore, the preferred installation
return side of the furnace. If return side installation is not possible, install
the unit on the supply side, keeping it as far from the heat/cooling source as
possible, and in the main airstream.

• Do not locate the unit within 20” of any plastic material that will be

exposed to the UV light, such as a return side humidifier or certain
filters. Check with the filter manufacturer to see if their material is U

V resistant.

Over time, UV light will degrade many plastic materials.

• Do not touch the glass portion of the lamp with bare hands because oils fro

m

the hands can cause “hot spots” which reduce lamp life. Handle either by th

e

porcelain caps or use a soft cloth. If you accidentally touch a lamp, wipe it o

ff,

using a soft cloth dampened with rubbing alcohol.

1. The ballast is factory set at 120 VAC. For installations that require

240 VAC locate the 120/240 volt power selector on the ballast and
set for the correct voltage. (Photo A)

2. Cut out the shaded area of the installation template.

insert.) Center the template on the longitudinal axis of the plenum

using tape to hold it in place. Trace the hole pattern for the unit
and mark centers for mounting screws.

3. Drill 9/64” holes for sheet metal screws and cut opening for the unit

.

4. Remove the cover from the unit using a 11/32 size nut driver to remove

the top and bottom retaining nuts and set aside.

5. Attatch the titanium reactor panel to

back of unit as an inverted “V” to
maximize airflow (as indicated in

photo A.) Use an 11/32 size nut driver

and the 8-32 keps nuts packaged with
sheet metal screws and fasten securely.

4. Attach unit to air duct using the four

sheet metal screws provided.

6. Remove germicidal lamp holder

(Figure A) using a 11/32 size nut driver.

7. Slide germicidal lamp into lamp opening.

8. Reinstall lamp holder.

9. Plug in lamp connector to the end of lamp.

10. Replace and secure cover using the

two retaining nuts.

(Figure A)

Germicidal

Lamp Holder

(Photo A)

8-32 keps nuts

(Photo B)