Danger – BVA Hydraulics PS33L User Manual
Page 2

2
SPECIFICATIONS
Model Number
(for use w/
single acting
cylinder)
Usable
Oil
Capacity
(gal)
Pressure Rating
(psi)
Output Flow Rate
(in
3
/min)
Valve
Type
Valve
Function
Motor
(HP)
Motor
Voltage
(V)
Weight
(lbs)
1st
Stage
2nd
Stage
1st
Stage
2nd
Stage
PES0501T
1
350
10,000
293
18
3-way,
3-position
Advance/
Hold/
Run
0.5
115
61.5
PES0502T
2
65.3
PES1002T
2
700
311
37
1
72.6
PES1503T
3
470
61
1.5
90.4
PES1505T
5
98
Inspect before each use. It is recommended that, prior to each use, an inspection be done by qualified personnel and that any
missing or damaged parts, decals, warning / safety labels or signs be replaced with factory authorized replacement parts only. Any
pump that appears to be damaged in any way, is worn, leaking or operates abnormally shall be removed from service immediately
until such time as repairs can be made. Any pump that has been subjected to a shock load (a load dropped suddenly, causing
the system pressure to exceed 10,000 PSI), shall be removed from service immediately until checked by qualified personnel.
Owners and operators of this equipment shall be aware that the use and subsequent repair of this equipment does require special
training and knowledge.
PRODUCT DESCRIPTION
This Pump is engineered to meet most industrial standards for Performance and Safety. Its allows quick displacement of hydraulic
fluid under no load conditions and easy pumping in loaded conditions. This electric hydraulic pump supplies compressed hydraulic
fluid to compatible applications i.e. rams, presses, spreaders, compactors and crimping machines, anywhere that 10,000 PSI of
fluid pressure is needed. Special skill, knowledge and training may be required for a specific task and the product may not be
suitable for all the jobs described above. Unsuitable applications would include applications that call for a device to move, level
or support persons, animals, hazardous materials, mobile homes/ dwellings in general, mirrors and/or plate glass, and/or to con-
nect/secure hatches, components, etc. between bulkheads. The user must make the decision regarding suitability of the product
for any given task and assume the responsibility of safety for himself/herself and others in the work area.
Save these instructions. For your safety, read and understand the information contained within. The owner and operator shall
have an understanding of this product and safe operating procedures before attempting to use this product. Instructions and
safety information shall be conveyed in operator's native language before use of this product is authorized. Make certain that the
operator thoroughly understands the inherent dangers associated with the use and misuse of the product. If any doubt exists as
to the safe and proper use of this product as outlined in this factory authorized manual, remove from service immediately.
Model Number
(for use w/
double acting
cylinder)
Usable
Oil
Capacity
(gal)
Pressure Rating
(psi)
Output Flow Rate
(in
3
/min)
Valve
Type
Valve
Function
Motor
(HP)
Motor
Voltage
(V)
Weight
(lbs)
1st
Stage
2nd
Stage
1st
Stage
2nd
Stage
PESM0501T
1
350
10,000
293
18
4-way,
3-position
Advance/
Hold/
Run
0.5
115
61.5
PESM0502T
2
65.3
PESM1002T
2
700
311
37
1
72.6
PESM1503T
3
470
61
1.5
72.6
PESM1505T
5
98
!
DANGER
TO AVOID ELECTROCUTION HAZARD:
• Owner, Operator must
read, understand and follow all printed material provided with this device before use.
• Connect
ONLY to properly grounded electrical source. Connect to GFI outlet ONLY! For use in dry locations.
• Do not operate this device in an explosive atmosphere or in the presence of conductive liquids.
• Avoid the use of extension cords. If necessary, for extension cords lengths up to 25 ft, use SJT-14X3 or heavier.
For cords up to 50 ft, use SJT-12X3 or heavier. For extension cord lengths up to 100 ft, use SJT-10X3 or heavier
NEVER use a 3 prong adapter.