Contents

Problem Solving Guide

After Installation Problems

Guarantee: If your lock should develop a fault within 1 year from date of purchase, due to inferior

materials or workmanship the goods will be repaired or replaced free of charge.
Please call our helpline for spares, repairs and technical advice

- UK: 0800 44 88 377

- International: +44 (0) 1708 225700
Disclaimer:
Under no circumstances should the lock be dismantled, this will invalidate our warranty.

Problem

Cause

Solution

The Latch cannot be withdrawn

when entering and turning the

knob.

The unit has been fitted to a Left hand

hung door.

All units are set to suit a right hand hung

door. The unit needs to be removed and

reversed. See `determing the hand of the

door’.

Both inside and outside knobs

retract when turned towards the

door frame.

The spindle has been set for the wrong

hand of door.

Remove the unit from the door and reposi-

tion the spindle. See ‘fitting & positioning

the spindle’

(page no.4).

The latchbolt does not move

smoothly in and out.

The lock has not been installed

correctly.

Check the the hole for the spindle in the

back of the keypad and inside handle are in

alignment with the hole in the latch. Check

that the latch is positioned horizontally and

the forend of the latch is parallel to the door

edge. Also check the spindle length, it may

be too long and binding against the inside

handle or keypad spindle holes.

The keypad knob turns after enter-

ing a correct code but does not

retract the latch.

The knob will not turn after the

code has been changed.

One or more of the buttons in the code

have been programmed incorrectly.

Re-read ‘how to change your code number’

on

(page no.7) and ensure that all of the

dials in the code are facing towards the

number down the centre.

The spindle has been cut too short or

has been positioned incorrectly.

If the spindle is too short it will not engage

with the keypad knob or inside handle. If

the spindle has been placed incorrectly

please refer to ‘fitting & positioning the

spindle’ (

page no.4).

Problem

Cause

Solution

The keypad knob turns freely with-

out having to enter any code.

The knob has been forcibly turned with-

out the correct code being entered.

Please call the Borg Locks helpline or return

the unit to Borg Locks or your distributor.

The inside handle lever does not

return to the upright position after

turning.

The handle return spring has broken.

Please call the Borg Locks helpline or visit

our website for a replacment.

The latch does not engage with

the strike and the door remains in

the open position.

The latch is to entering the hole in the

strike plate.

Your door or frame may have warped since

the lock was installled. Check that the latch-

bolt is inline with the hole in the strike plate.

Re-align position of the stike if necessary.

Make sure the anti-thrust pin on the latch

does not enter the hole in the strike plate.

V1

Code Card
C#####

Borglocks

1

2

3

4

5

6

7

8

9

10

11

12

13

14

1.

Keypad

2. Inside handle

3. Gaskets (x2)

4. Tubular Latch

5. Strike Plate & Box Keep

6. Holdback Snib Blank

(Holdback Models Only)

7. Latch Support Post

8. Hexagon Support Posts

9. Spindle

(100mm)

10. Spindle

(85mm)

11. Machine Screws

(50mm)

12. Machine Screws

(35mm)

13. Wood Screws

(15mm)

Installation Problems

8

14. Code Card

borglocks.com

1

2

3

4

5

Y

6

7

8

9

0

C