Atec Sorensen-SFA Series User Manual

Sorensen sfa series 5–150 kw, High slew rate current source

background image

858.458.0223

[email protected]

Sorensen SFA Series

5–150 kW

High Slew Rate Current Source

60–160 V

31–2500 A

208

400

480

The SFA family builds on the industry leading
Sorensen SGA series to provide a high power
current source for laser diode applications. State
of the art high power laser diodes require well-
regulated current control to avoid catastrophic
damage. Under anomalous operating conditions,
excessive stored energy in the output circuit of
the power supply can result in peak stresses that
can permanently damage the device. Providing a
constant current regulation mode only, the SFA’s
low stored energy output minimizes damage
potential for sensitive devices as well as enabling
a current slew rate of up to 400 A/msec.

Specifications (at nominal AC line and 25ºC)

Output Slew Rate (10-90% resistive load) 250A/ms (400A/ms typical) rise, 200A/ms typical fall; 160V model 87A/ms/5kW (145A/ms/5kW typical), 60A/ms, typical, fall
Control Mode

Current Control Only

Front Panel Meter Accuracy

Voltage ±0.5% of full-scale + 1 digit, Current ±0.5% of full-scale + 1 digit

Load Regulation

(no load to full load, nominal AC input) Current 0.1% of rated output current

Line Regulation

(±10% of nominal AC input) Current 0.05% of rated output current

Current Ripple

1% p-p of full-scale current

Transient Response

Output current recovers to within 1% of current setpoint within 1ms for a 10 to 100% or 100% to 10% step load change

Current Overshoot

Maximum 8% of full-scale for 0 to 100% change into a resistive load

Output Capacitance

60V Models <10 µF / 5 kW, 100/160V Models 3 µF / 5 kW

Stability

±0.05% of setpoint after 8–hr. warm-up at fixed line, load, and temperature using remote sense

Power Factor

>0.9 typical for 208/220VAC input, >0.78 typical for 380/400VAC input, >0.7 typical for 440/480VAC input

Remote Analog Control

Current Setpoint Accuracy, ±0.8% of full-scale output; Overcurrent Protection, ±1% of full-scale output;
Resistive Control, 0–5kΩ = 0-100% Current; Voltage Control, 0–5 or 0–10 VDC = 0-100% Current;
Overcurrent Protection, 0–5.5 VDC = 0-110%

Efficiency

87% typical at full load, nominal line

Remote Control/Monitor

On/Off control via contact closure, 6-120 VDC or 12-240VAC, and TTL or CMOS switch, current monitor, OCP limit set,
summary fault status

Overvoltage Protection

Fixed at approximately 110% of the rating compliance voltage. Reset requires cycling the front panel standby power switch off/on

Ethernet Control (optional)

LXI compliant 10/100 Base T Ethernet remote control with web server for direct control of power supply via web browser.

Isolated Analog Control (optional)

Input to Output Isolation: 500 V Compliant with max. terminal float voltage. Recommended operation under SELV normal conditions.

Regulatory

Certified to UL/CSA 61010 and IEC/EN 61010-1, CE Compliant (LVD and EMC Directives), Input power options

Input Power Configuration

3–phase, 3–wire plus ground. Not phase, rotation sensitive. Neutral not used.

Input Power Voltage Selection

208/220 VAC±10%, 47 to 63 Hz, 380/400 VAC±10%, 47 to 63 Hz, 440/480 VAC±10%, 47 to 63 Hz

Environmental

Ambient Operating Temperature

0 to 50°C

Storage Temperature

-25 to 65°C

Temperature Coefficient

Current Setpoint 0.03%/°C of rated current

Cooling

Internal Fans. Zero clearance stacking

Humidity

0 to 90% at 40°C; 0 to 50% at 25°C, non-condensing

Altitude

Full power at 5,000 feet, 10% derating of full power for every 1,000 feet above 5,000 feet

Physical

5 to 15 kW in 3U

19.00in W x 25.12in D x 5.25inH; 80 lbs., (48.3cm W x 63.8cm D x 13.3cm H; 36 kg)

20 - 30 kW in 6U

19.00in W x 25.12in Dx 10.5in x H; 160 lbs., (48.3cm W x 63.8cm D x 36.7cm H; 73 kg)

Accessories

Modifications

AJ: Front panel dust filter - factory installed - 3U unit only

K550212-01 / 5550568-01

3U Rack Slides (for 5kW, 10kW and 15kW models) / Front panel dust filter - field installation kit - 3U unit only

K550213-01 / 9550589-01

6U Rack Slides (for 20kW, 25kW and 30kW models) / AC input cover - 3U unit only

3U

6U

Power

5 kW

10 kW

15 kW

20 kW

25 kW

30 kW

Voltage

Maximum Current

(parallel for higher current. )

60

83

167

250

333

417

500

100

50

100

150

200

250

300

160

31

63

94

125

156

188

83