beautypg.com

Infinity Drain TD 15 Installation Instructions User Manual

Series, Parts list, Td 15 & td 20 installation

background image

TD

Series

TD 15 & TD 20 Installation

Infinity Drain recommends this product be

installed by a licensed contractor

Parts List

(C) 4″ clamp
down drain*

with 2" or 3" connect

(*Included in kit)

Weep holes

Waterproofing
membrane

(A) Top frame

(B) Bottom frame

1. Determine clamp down drain

(C) location. Connect to drain pipe.

2. Create a pre-slope in four directions

towards drain body (C). Waterproof
to local code.

3. Insert bottom frame (B) into clamp

down drain (C) and adjust height
as needed. Allow secondary mortar
bed to support bottom frame (B).

4. Remove top frame (A) and install

tile within frame, using mortar and
thin set.

5. Finish floor must be 1/16″ higher

than top edge of bottom frame (B).

Installation Instructions

Figure 1

Determining floor height

Finished floor height must be 1/16″ higher at top edge of Infinity Drain

Minimum height

≈ 1⅞″

Maximum height

≈ 2¾″

5

1 ⅜"

TD 15

7 ⅞

TD 20

Figure 2

TD 15

TD 20

TKEY to lift top grate

1 ⅜"

4

1/16″

7

1/16″

Interior dimension

Interior dimension

18 Secatoag Avenue, Port Washington, New York 11050 ● p:516.767.6786 f:516.740.3066 www.infinitydrain.com