AVSL 600.102 MTB02 User Manual
Page 7
MTB01 & MTB02 User Manual
Resistance
RANGE
RESOLUTION
ACCURACY
200Ω
0.1Ω
± (1.0% of rdg + 10D)
2000Ω
1Ω
20kΩ
10Ω
200kΩ
100Ω
± (1.0% of rdg + 4D)
2000kΩ
1kΩ
MAXIMUM OPEN CIRCUIT VOLTAGE: 3V
OVERLOAD PROTECTION: 15 seconds maximum 220Vrms
OPERATING INSTRUCTIONS
DC & AC VOLTAGE MEASUREMENT
1. Connect red test lead to “VΩmA” jack, black lead to “COM”
jack.
2. Set RANGE switch to desired VOLTAGE position, if the voltage
to be measured is not known beforehand, set switch to the
highest range and reduce it until satisfactory reading is
obtained.
3. Connect test leads to device or circuit being measured.
4. Turn on power of the device or circuit being measured voltage
value will appear on Digital Display along with the voltage
polarity.
DC CURRENT MEASUREMENT
1. Red lead to “VΩmA”. Black lead to “COM” (for measurements
between 200mA and 5A connect red lead to “5A” jack with fully
depressed.)