beautypg.com

2 voltage limit shift-key, Operation – American Magnetics 4Q06250PS-430 High Stability Integrated Power Supply System User Manual

Page 54

background image

36

Rev. 5

Operation

Shift Key Commands : Voltage Limit

the new “limit” falls within the range of segment 2. The display for

segment 2 range will now appear as follows

1

.

The unused segment(s) will remain in memory (retaining their

original parameters) until one or more become active again as the

Current Limit is raised into or above the respective ranges. When

displayed, the higher-range unused segments will show a range of

“±Limit to ±Limit” until re-activated

2

.

If the Current Limit is raised above the Magnet Current Rating, it

will be ignored and the actual Magnet Current Rating will govern.

3.7.2

Voltage Limit SHIFT-key

Use of the

VOLTAGE LIMIT

SHIFT-key provides a menu for setting the

limit for output voltage for the power supply the Model 430 Programmer

controls. This value should be set to a high enough value so that under

normal conditions, the Voltage Limit is never reached. The value can be

set by using either the numeric keypad per section 3.3 on page 25 or the

fine adjust knob (section 3.4 on page 26). Note that the voltage drop in the

leads must be accounted for when setting the Voltage Limit, as well as the

voltage drop of an energy absorber if one is used (see section 3.12 on

page 74 for details of how to determine the appropriate Voltage Limit).

The Voltage Limit may be set less than or equal to the maximum output

voltage of the power supply.

3

The Voltage Limit does not require a sign

since it functions as both the negative and positive limit.

1. If the value were to be set below 55 A, only segment 1 would be active, and would

display the upper bound of “±Limit”.

2. Also if the number of segments is increased, the new segments are added to the

upper end of the ramp range, and default to the ramp rate of the previous segment
with the range of +/-Limit to +/-Limit until set up.

3. Refer to Table 3-2 on page 45.

+50.00 A - Seg.2 Range (A)

+0.50 Vs

±55.0 to ±Limit

+50.00 A - Seg.3 Range (A)

+0.50 Vs

±Limit to ±Limit

+50.00 A - Voltage Limit (V)

+0.50 Vs

±2.000