OPERATION INSTRUCTIONS FOR THE AIRFLOW
BREEZE ULTRA WITH REMOTE CONTROL
MODEL SERIES 7.1
READ AND SAVE THESE INSTRUCTIONS AND
IMPORTANT NOTICE
INSTALLATION:
Floor registers 6”x10” or 6”x12”
1. Remove the round cap on the grill top.
2. Route the plug end of the AC adapter through the
round
opening and plug into the underside of the Ultra.
3. Place round cap with slot on the grill top.
4. Plug the AC adapter into the 120V AC wall outlet
.
5. Follow the Operation Settings.
6. Remove the floor register and replace with the U
ltra.
Wall or Ceiling registers 6”x10” or 6”x12”
1. Drill (2) holes with a 3/16” drill bit from the bottom side of the
Breeze. The holes should be drilled in the pre-mol
ded
locations as pictured below.
2. Remove the round cap on the grill top
3. Route the plug end of the AC adapter through the
round
opening and plug into the underside of the Ultra.
4. Place round cap with slot on the grill top.
5. Plug the AC adapter into the 120V AC wall outlet
.
6. Follow the Operation Settings.
7. Remove the wall or ceiling register and replace
with the
Ultra.
Note: If you choose to hard wire the Ultra, install the n
ecessary 120V
AC outlet near the backside of the Ultra then plug
into the rear of the
unit. Use the non-slotted grill cap to trim out th e Ultra top.
Power Receptacle Po
wer Cord Access Hole
Wall and Ceiling Drill
Hole Locations
6” X 10” 6” x 12”
Operation Settings
:
Mode Selections:
•
FAN (green) for continuous running
•
HEAT (red) for automatic ON/OFF to boost warm air
•
COOL (blue) for automatic ON/OFF to boost cool air
Display shows SET POINT
temperature setting for
HEAT and COOL
FAN Speed Settings
REMOTE CONTROL INSTRUCTIONS
•
Press ON/OFF button to turn Breeze Ultra on.
•
Press MODE button for FAN (green) and select fan s
peed
(Suggest HIGH to start.)
•
For heating press the MODE button and select HEAT (red).
Adjust SET POINT down until fans ar
e on, then
adjust SET POINT up until fans turn off. Unit is
now set.
•
For cooling press MODE button and select COOL (blue).
Adjust SET POINT up until fans are on, and then adj
ust
SET POINT down until fans turn off. Unit is now se
t.
•
Return to INSTALLATION directions #6 or #7.
UP
DOWN
IMPORTANT NOTES
1. Fan speed light will flash when fans are running
.
2. Fan speed can be set at any time. Fans do not h
ave to be
running.
3. Numeric display will go out 30 seconds after SET
POINT is
completed.
4. The numeric display will only be active in the H
eat or Cool mode.
5. The numeric display will come on in Heat or Cool
if any button is
pressed.
6. The numeric display exhibits an approximate room
temperature
for the purpose of programming the electronic senso r.
7. To shorten the length of time your Breeze Ultra
runs after your
forced air furnace or air conditioner has shut off
a. for HEAT raise the SET POINT temperature
b. for COOL lower the SET POINT temperature
8. If power fails or the Breeze Ultra is turned off
the Ultra will
automatically retain all settings.