Select_card_type, Reset, Set_notification – ACS AET63 BioTRUSTKey User Manual
Page 14

7.1.2.
SELECT_CARD_TYPE
This command sets the required card type. The firmware in the AET63 adjusts the communication
protocol between reader and the inserted card according to the selected card type.
Command format
Instruction Code
Data length
Data
TYPE
02
H
01
H
TYPE
See Appendix A for the value to be specified in this command for a particular card to
be used.
Response data format
No
response
data
7.1.3.
RESET
This section describes the RESET command only for the case when no card type is selected or when
the card type 00
H
is selected. For all other cases, please refer to the specific section described for
each individual card type.
Command format
Instruction
Code
Data length
80
H
00
H
Response data format
ATR
ATR
The answer-to-reset string returned by the card.
The return status code for this command is 90 00
H
when the inserted card is a T=0 card, 90 01
H
when
the inserted card is a T=1 card, and 90 10
H
when the inserted card is a memory card; otherwise the
status code is 60 20
H
.
7.1.4.
SET_NOTIFICATION
This command disables / enables the Card Status Messages transmitted by the reader to notify the
host computer of the insertion or removal of a card.
Command format
Instruction
Code
Data length
Data
NOTIFY
06
H
01
H
Document Title Here
Document Title Here
Document Title Here
AET63 Reference Manual
Version 2.2
Page 14 of 26
www.acs.com.hk