The four BREATH parameters listed below determine just how the breath controller

will affect the DX27’s sound. These parameters may be set individually, or combined
for more complex effects.

20

: BREATH RANGE, PITCH

This function is used to set the maximum depth of LFO pitch modulation that can

be applied using the breath controller. The actual effect produced depends on the

settings of the LFO parameters-these will be discussed in

CHAPTER IV:

VOICE

PROGRAMMING. Note, however, that the appropriate voice PITCH MODU-
LATION SENSITIVITY parameter must be set to a value higher than 0 for pitch
modulation to be effective. The voice PITCH MODULATION SENSITIVITY pa-
rameter will be discussed in

CHAPTER IV:

VOICE PROGRAMMING.

The data range is from 0 to 99. At 0, pitch modulation is OFF, and applying breath

pressure to the breath controller will cause no pitch modulation to be applied to

the voice. A setting of 99 produces the greatest possible pitch modulation depth.

Data is entered using the DATA ENTRY sliderand -1/+1 buttons. Once this function

is called, subsequent presses on the 20 button will increment the data value.

21:

BREATH RANGE, AMPLITUDE

This function is used to set the maximum depth of LFO amplitude modulation that
can be applied using the breath controller. The actual effect produced depends

on the settings of the LFO parameters-these will be discussed in

CHAPTER IV:

VOICE PROGRAMMING. Note, however, that the appropriate voice AMPLITUDE

MODULATION SENSITIVITY parameter must be set to a value higher than 0 for

amplitude modulation to be effective. The voice AMPLITUDE MODULATION

SENSITIVITY parameter will be discussed in

CHAPTER IV:

VOICE PROGRAM-

MING.

The data range is from 0 to 99. At 0, amplitude modulation is OFF, and applying

breath pressure to the breath controller will cause no amplitude modulation to be
applied to the voice. A setting of 99 produces the greatest possible pitch modulation

depth.

Data is entered using the DATA ENTRY slider or -1/+1 buttons. Once this function
is called, subsequent presses on the 21 button will increment the data value.

22

: BREATH RANGE, PITCH BIAS

This function permits breath pressure applied to the BC-1 breath controller to directly
control the pitch of the voice. In other words, the LFO has no effect. Only your

breath pressure directly affects the pitch of the voice.

The data range is from 0 to 99. At 50, pitch bias is OFF. A setting of 99 permits
a 4-octave pitch increase, and a setting of 0 permits a 4-octave pitch decrease to

be produced through the breath controller.

Data is entered using the DATA ENTRY slider and -1/+1 buttons. Once this function

is called, subsequent presses on the 22 button increment the data value.

15