Western Telematic AT COMMAND SET MT9234 User Manual
Page 16

3-8
MT5634/MT9234 Modem; AT Command Set
Command: &Tn
Loopback Test (V.54 Test) Commands
Values:
n = 0, 1, 3, 6
Default:
None
Description:
The modem can perform selected test and diagnostic functions. A
test can be run only when the modem is operating in non-error-
correction mode (normal or direct mode). For tests 3 and 6, a
connection between the two modems must be established. To
terminate a test in progress, the escape sequence (+++AT) must
be entered.
&T0 Stops any test in progress.
&T1 Starts a local analog loopback, V.54 Loop 3, test. If a
connection exists when this command is issued, the
modem hangs up. When the test starts, a CONNECT
message is displayed.
&T3 Starts local digital loopback, V.54 Loop 2, test. If no
connection exists, ERROR is returned.
&T6 Initiates a remote digital loopback, V.54 Loop 2, test
without self-test. If no connection exists, ERROR
is returned.
Command: &V
Display Current Settings
Values:
N/A
Description:
Displays the active modem settings.
Command: &Wn Store Current Configuration
Values:
n = 0 or 1
Default:
1
Description:
&W0 Stores current modem settings in non-volatile memory
and causes them to be loaded at power-on or following
the ATZ command instead of the factory defaults.
See &F command.
&W1 Clears user default settings from non-volatile memory
and causes the factory defaults to be loaded at power-on
or following the ATZ command.
Command: &Zy=x Store Dialing Command
Values:
y = 0–2 (0–1SMI-Parallel {internal})
x = Dialing command
Default:
None
Description:
Stores dialing command
x in memory location y. Dial the stored
number using the command ATDS=y. See Also the #CBS
command, a callback security command.