Some Points to Remember

Learn to recognize the odor of LP Gas. Your local LP Gas dealer can give you a ”Scratch and Sniff” pamphlet. Use
it to find out what the propane odor smells like. If you suspect that your LP Gas has a weak or abnormal odor, call
your LP Gas dealer.

• If you are not qualified, do not light pilot lights, perform service, or make adjustments to appliances on the LP Gas
system. If you are qualified, consciously think about the odor of LP Gas prior to and while lighting pilot lights or
performing service or making adjustments.

• Sometimes a basement or a closed–up house has a musty smell that can cover up the LP Gas odor. Do not try to
light pilot lights, perform service or make adjustments in an area where the conditions are such that you may not detect
the odor if there has been a leak of LP Gas.

• Odor fade, due to oxidation by rust or absorption on walls of new cylinders and tanks, is possible. Therefore, people
should be particularly alert and careful when new tanks or cylinders are placed in service. Odor fade can occur in
new tanks or reinstalled old tanks if they are filled and allowed to set too long before refilling. Cylinders and tanks
which have been out of service for a time may develop internal rust which will cause odor fade. If such conditions
are suspected to exist, a periodic sniff test of the gas is advisable. If you have any question about the gas odor,
call your LP Gas dealer. A periodic sniff test of the LP Gas is a good safety measure under any condition.

• If, at any time, you do not smell the LP Gas odorant, and you should, assume you have a leak. Then take
the same immediate action recommended when you do smell the odorized LP Gas.

• If you experience a complete ”gas out” (the container is under no vapor pressure), turn the tank valve off immediately.
If the container valve is left on, the container may draw in some air through openings such as pilot light orifices.
If this occurs, some new internal rusting could occur. If the valve is left open, then treat the container as a new tank.
Always be sure your container is under vapor pressure by turning it off at the container before it goes completely
empty or having it refilled before it is completely empty.

Technical Data

kW 4.25

mbar

7.7

OUTPUT HEATING CAPACITY

kBTU/hr 14,514

NATURAL

GAS

in

W.C.

3.1

kW 5.19

mbar

26.4

INPUT RATING

kBTU/hr 17,700

MAX

LP

in

W.C.

10.6

kW 3.84

mbar

4.6

MINIMUM INPUT RATING
(LO Input)

kBTU/hr 13,100

NATURAL

GAS

in

W.C.

1.8

THERMAL EFFICENCY

%

82.00

mbar

16.3

mm 553

MANIFOLD PRESSURE

MIN

LP

in

W.C.

6.6

LENGTH

in 21-3/4

m

3

/h 0.5

mm 715

NATURAL

GAS

ft

3

/h 17.8

HEIGHT

in 28-1/8

m

3

/h 0.2

mm 208

MAX

LP

ft

3

/h 6.9

DEPTH

in 8-1/4

m

3

/h 0.4

kg 26

NATURAL

GAS

ft

3

/h 13.3

WEIGHT

lbs. 57

m

3

/h 0.1

GAS CONNECTION

NPT

3/8

FEMALE

GAS RATE

MIN

LP

ft

3

/h 5.3

mm 50

mbar

17.4

WALL HOLE DIAMETER

in 2

NATURAL

GAS

in

W.C.

7.0

mm 49

mbar

27.4

AIR INLET DIAMETER

in 1-7/8

MINIMUM INLET

PRESSURE

LP

in

W.C.

11.0

mm 35

m

3

/h 220

EXHAUST PIPE DIAMETER

in 1-3/8

AIR FLOW

cfm 129

mm 150

m

3

/h 160

MIN WALL THICKNESS

in 5-7/8

MINIMUM AIR FLOW

cfm 94

mm

500

TOTAL ELECTRICAL LOAD

W

86

MAX WALL THICKNESS

in 19-5/8

3

This manual is related to the following products: