Troubleshooting 27, Operation summary – Whistler 2000 WATT User Manual
Page 15
TROUBLESHOOTING
27
PROBLEM: TV Interference
Problem
Solution
Electrical interference from
Add a Ferrite data line fil-
ter inverter.
on to the TV power cord.
This filter is available at
RadioShack, or other
electronic supply stores.
part number 273-105.
PROBLEM: Low or No Output Voltage
Problem
Solution
Using incorrect type of
Use true RMS reading meter
voltmeter to test output
See "For You Technical
voltage.
Types"
Section of this manual.
PROBLEM: Low Battery Alarm On All The Time
Problem
Solution
Input voltage below
Keep input voltage above
11 volts.
11 volts to maintain
regulation.
Poor or weak battery
Replace battery.
condition.
Inadequate power being
Use lower gauge wire. See
delivered to the inverter
“Wire Cable Gauges”
or excessive voltage drop.
section of this manual.
Keep wire length as short
as possible.
OPERATION SUMMARY
•
Avoid placing the inverter near sources of heat or in
direct sunlight.
•
When in use, make certain that the inverter is properly
ventilated.
•
Do not use the inverter near flammable materials,
fumes, or gases.
•
Always operate the inverter in accordance with the
instructions in this manual. Failure to do so may result
in property damage, personal injury, or loss of life.
•
While connecting the inverter to the power source,
make certain that the inverter is well removed from
any potential source of flammable fumes or gases.
•
Always ground the inverter before operating it.
•
In the event a continuous audible alarm or automatic
shut off, turn the inverter OFF immediately. Do not
restart the inverter until the source of the problem has
been identified and corrected.
26