beautypg.com

Query status of the digital output – Vivotek FD6111V User Manual

Page 84

background image



- 80 -

www.vivotek.com

T: 886-2-82455282
F: 886-2-82455532


HTTP/1.0 200 OK\r\n
Content-Type: text/plain\r\n
Content-Length: \r\n
\r\n
[di1=]\r\n
[di2=]\r\n
[di3=]\r\n
[di4=]\r\n
where can be H or L.

Example: Query the status of digital input 1
Request:

http://myserver/cgi-bin/getdi.cgi?di1


Response:
HTTP/1.0 200 OK\r\n
Content-Type: text/plain\r\n
Content-Length: 7\r\n
\r\n
di1=H\r\n

Query status of the digital output

Note: This request requires the privilege of I/O access control.
Method: GET/POST

Syntax:
http://<servername>/cgi-bin/getdo.cgi?[do1][&do2][&do3][&do4]

If no parameter is specified, all the status of digital output will be returned.

Return: