Ventilation Dehumidistat

PART NO. 99-116

The High/Low Speed Switch initiates High or Low speed ventila-
tion. This control also has an ON/OFF Switch and a
Dehumidistat Dial (refer to "The ON/OFF Switch" and "The
Dehumidistat Dial" descriptions).

Recirculation Control

PART NO. 99-RECIRC

Note: For use with RNC95 only

The Recirculation Switch will toggle from continuous low speed
ventilation to recirculation mode (closes the fresh air damper and
circulates the building air). The Dehumidistat Dial will initiate
High Speed ventilation when the indoor humidity level exceeds
the set point (regardless position of the RECIRC Switch.). This
control also has an ON/OFF Switch and a Dehumidistat Dial
(refer to "The ON/OFF Switch" and "The Dehumidistat Dial"
descriptions).

20 Minute Timer

PART NO. 99-132

Connects to RED, BLACK and GREEN
(LED drive) terminals. Use a minimum of
three 20 gauge low voltage wire. Connect
up to 4 on 100 ft (91 m) wire max. Mounts in
a 2 x 4 box.

DEHUMIDIST

AT

Off

10

20

30

40

50

60

Optional Main Controls

The amount of ventilation required in your home will fluctuate
according to the activity level in the house. Higher activity levels
require more ventilation.

Main controls can be mounted in a central location of the home
(i.e. beside the furnace thermostat) which will provide the user
with complete control over their ventilation system from a conve-
nient location.

The ON/OFF Switch

The ON/OFF Switch will turn the HRV ON or OFF. Controls with
an ON/OFF switch can be modified to ON/Standby by adjusting

the circuit board DIP Switches (Refer to "Mode DIP Switch
Settings").

The Dehumidstat Dial

Main controls feature a dehumidistat dial. The dehumidistat is
used to reduce high winter humidity levels. The dehumidistat
activates high speed ventilation when the indoor humidity level
exceeds selected setting.

Optional Timers

Timers should be present when the HRV is exhausting from
specific locations i.e bathrooms, laundry rooms. The 20 Minute

Timer is the best selection, however, the crank timer will be nec-
essary if only 2 lead low voltage wires are present.

Only one main control can be installed on your
system.

ATTENTION

Dehumidistat
Dial

High/Low
Speed Switch

ON/OFF
Switch

Crank Dial
Rotate the dial for up to 60
minutes high speed opera-
tion.

D e h u m i d i s t a t
Dial

Recirculation
Switch

ON/OFF
Switch

20/40 ON/OFF Dehumidistat

PART NO. 99-2040

The 20/40 Switch will toggle from continuous low speed ventila-
tion to an intermittent mode of 20 minutes fan ON (in low speed)
and 40 minutes fan OFF. The Dehumidistat Dial will initiate High
Speed ventilation when the indoor humidity level exceeds the set
point (regardless position of the 20/40 Switch.). This control also
has an ON/OFF Switch (refer to "The ON/OFF Switch" descrip-
tion).

Remote Dehumidistat

PART NO. 99-130 White

The Remote Dehumidistat activates high speed ventilation when
the indoor humidty level exceeds the set point.

Dehumidistat
Dial

20/40

Switch

ON/OFF
Switch

Dehumidistat
Dial

Crank Timer

PART NO. 99-101

Connects to RED and BLACK termi-
nals. Use a two 18 gauge low
voltage wire. Mounts in a 2 x 4 box.
The crank timer provides a solution
to installing a system where only 2
wires are present for the timers.

20 Minute Status Lights
The 20 Minute Status Light indicates
high speed operation is activated.

Touch Pad
The Touch Pad initi-
ates

high

speed

operation.

Remote Control Devices