beautypg.com

PSC Scanners User Manual

Page 51

background image

06656

45

The minimum length of Code 39 messages is set by scanning Option
OH, followed by scanning two digits (01-32) from the Digit Selection
page.

The maximum length of Code 39 messages is set by scanning Option
OI, followed by scanning two digits (01-32) from the Digit Selection
page. If the minimum and maximum values are set equal, only codes
of that exact length are read.

The START and STOP characters in code 39 may either be transmitted
or suppressed. Scan Option OF to suppress transmission of the
START and STOP characters. Scan Option OG to enable transmission.

OF

Do Not XMIT START and STOP*#@

OG

Transmit START and STOP

The following are only valid if CHK CHAR is enabled.

OH

Minimum Length (specified by
two digits 01-32)

OI

Maximum Length (specified by
two digits 01-32)

OJ

Enable Transmission of Code 39
Modulo 43 Check Character

OK

Disable Transmission of Code 39
Modulo 43 Check Character *