1000 universal gateway – Lucent Technologies APX 1000 User Manual
Page 3

APX
®
1000 Universal Gateway
 
 
 
Hardware Technical Specifications 
 
8. Physical Dimensions 
 14.8” (D) x 17.2” (W) x 5.20” (H) (3 rack units) 3RU 
 Loaded system weight: 39 lbs. (approximate) 
 
9. Chassis Architecture 
 6 slots total 
 1 dedicated slot for system controller module 
 1 dedicated slot for channel ingress card 
 4 general purpose slots for port processing, circuit and 
 packet modules 
 
10. Universal Port Density 
 576 voice/data calls – via Channelized T1 
 672 voice/data calls – via Channelized DS3 
 720 voice/data calls – via Channelized E1 
 
11. Serviceability/Redundancy 
 Packet, circuit and processing modules hot-swappable 
 All modules and fan tray field-replaceable 
 Three (3) independent cooling fans with system 
 monitored fan-fail signals removable fan tray 
 AC and DC power supply units 
- Hot-swappable, 1+1 redundant, load sharing, AC
input and DC input power supplies
 - Mixed AC & DC supplies supported in the same 
 chassis 
 
12. APX
®
1000 Universal Gateway Module Options
 WAN Access Modules 
 Circuit switching (ingress) 
 – 24-port Channelized T1/E1 
 – 8-port Channelized E1 
 – 8-port Channelized T1 
 – 1-port Channelized DS3 
 Packet switching (egress) 
 – 1-port OC3/STM-1 ATM (copper or short-haul fiber or 
 long-haul fiber) 
 – 2- and 4-port 10/100 fast Ethernet 
 Processor Modules/CODEC Support 
 288-port MultiDSP / G.711, G.729 (a and b), G.723.1 
 240-port MultiDSP / G.711, G.729 (a and b), G.723.1 
 96-port MultiDSP / G.711, G.729 (a and b) 
 2nd- generation HDLC 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
13. Power Requirements 
 Power budget AC 
 Total typical values per fully loaded chassis: 
 Input power per chassis: 381 W 
 Heat dissipation: 959 BTU/h 
 Current intake @ 100Vac input: 9.6 A* 
 Current intake @ 115Vac input: 7.0 A* 
 Current intake @ 230Vac input: 3.5 A* 
 Recommendations: 
 Input power per chassis: 337 W 
 Heat dissipation: 1150 BTU/h 
 Current intake @ 100Vac Input: 9.6 A* 
 Current intake @ 115Vac Input: 8.5 A* 
 Current intake @ 230Vac Input: 4.2 A* 
 Power budget DC 
 Total typical values per fully loaded chassis: 
 Input power per chassis: 301 W 
 Heat dissipation: 1027 BTU/h 
 Current intake @ -48Vdc input: 16.0 A* 
 Current intake @ -40Vdc input: 20.0 A* 
 Recommendations: 
 Input power per chassis: 361 W 
 Heat dissipation: 1233 BTU/h 
 Current intake @ -48Vdc input: 20.0 A* 
 Current intake @ -40Vdc input: 24.0 A* 
 Configuration: 
 1 x controller module, 3 x 288-port MultiDSP modules, 
 1 x DS3, 
 1 x Ethernet, 1 fan tray 
 
 * Per power supply 
 
14. Operating Characteristics 
 Ambient operating temperature: 
 -0 C to 40 C (-5c to +55c for short term per GR63- 
 CORE) 
 Ambient storage temperature: 
 -40 C to +65 C 
 Relative humidity: 
 10% to 95% non-condensing 
 Operating altitude: 
 to 10,000 feet (3,050 M) 
 
15. Regulatory Compliance 
 NEBS: Level 3 compliant, GR-63-CORE, GR-1089- 
 CORE, CLEI coded, available in TIRKS database 
 EMC/EMI: FCC 15 Class A, R&TTE Directive (EN 
 55022, EN 300 386), Class A, EN 61000-3-2, EN 
 61000-3-3, AS/NZS 3548, Class A, CISPR 22 Class A, 
 VCCI Class A, CNS 13438 Class A 
 Safety: CSA NRTL (UL 1950, Third Edition), CSA 
 C22.2, No. 950, Third Edition, R&TTE Directive EN 
 60950 Including Amendments 1, 2, 3, 4, 11, IEC 
 60950 including Amendments 1, 2, 3, 4 
 Telecom: FCC Part 68, IC CS 03, JATE 
 