beautypg.com

Set temperature, Options, Options: level 1 (operator) – La Pavoni P180 User Manual

Page 16

background image

Pag. 16

SET TEMPERATURE


This menu has the following parameters:

SET BOILER TEMPERATURE

Setting the boiler temperature.


TIME OVERHEATING BOILER

If the machine hasn’t worked for a long time, the boiler will overheat.


SET OVERHEATING BOILER

Boiler overheating value (max. 5°C).


TIME FILLING UP BOILER

The pump refills the boiler to keep the maximum level at the set time


SET FILLING UP BOILER

Boiler refilling time.



OPTIONS


This menu has 2 different levels that are protected by a password:

1st level. Operator - addressed to the machine operator
2nd level. Manager - addressed to the machine technician / manager


The machine has 3 working types that have their own selections and amounts
counter:

standard:

standard working with priced selections

test :

working with priced selections and with the money that
doesn’t go into the coin box (example: the technician has
to test the machine and the payment system).

Free test:

working with free selections.



The counters of every level are independent; therefore the zero resetting of the
counters of a level doesn't influence the other counters

Pag. 17

OPTIONS: LEVEL 1 (operator)


After you have inserted the correct password, which initially is “111”, the follow-
ing menu will appear:

MODIFY PASSWORD LEVEL 1: Insert the new password and press E to con-
firm it.

TEST MACHINE MODE: Set the machine in test mode working.

FREE MODE: Set the machine in free mode working.

SINGLE DRINK COUNTERS&AMOUNTS: Choose the id drink to analyse

with + or - and press Enter to confirm.

REGULAR COUNTERS: standard working counter.
TEST MODE COUNTERS&AMOUNTS: Test mode working counter.
FREE MODE COUNTERS&AMOUNTS: Free mode working counter.


RESET COUNTERS&AMOUNTS: Above counters zero resetting:
Press "6" to reset or "5" to cancel.