beautypg.com

Operating the fireplace, Fireplace installation – LG ELITE ME43BK SP User Manual

Page 5

background image

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

5

OPERATING THE FIREPLACE

Fuel

The ME43 fireplace is designed to work best

when fueled with seasoned cordwood. Hard-

woods are preferred to softwoods since the

energy content of wood is relative to its density.

Hardwoods will result in a longer burning fire

and less frequent refueling. A moisture con-

tent of 15% to 20% (seasoned) is preferred.

Excessively wet wood will be difficult to burn

and will result in lower efficiency and increased

creosoting.

Do not burn scrap or garbage, treated wood or

wood such as driftwood from the ocean which

has been exposed to salt or other chemicals.

Salt or chemicals can corrode the firebox and

chimney. Do not abuse the unit by burning

large amounts of paper, cardboard, Christmas

tree branches or building construction materi-

als such as pressed wood, plywood or lumber.

Intense firing with these may overheat the

fireplace, causing damage to the unit, a fire,

or even possibly igniting a chimney fire, if the

chimney is creosoted.

First Fires

The first 5 or 6 fires should be small fires of

short duration (about 30-60 minutes). The first

fire should be especially short. This will help

cure the refractory bricks. The first fires may

produce slight smoking and some odor due

to drying of the paint and steel and any dust

accumulated on the fireplace will be burn off at

this time. For this reason the room should be

well ventilated during the first few fires.

Building A Fire

To start a fire, place several crumpled up balls of

newspaper in the firebox. Place small dry pieces

of kindling on top of the paper, crisscrossing the

kindling so that there is airspaces in between.

Place the larger pieces of kindling on top of the

pile. Keep the fuel far back enough so that air

can get underneath. Open the air control fully

and light the newspaper. Once the kindling fire

is well established, cordwood can be added.

The unit will burn best with a minimum of two

pieces of cordwood spaced 1" to 2" apart and al-

lowing air to get under the fuel. Crisscrossing or

arranging the fuel so that air can get underneath,

will help the fire to get started easily.

Figure 2

HOW TO USE THE RETRACTABLE DOORS

AND FIRESCREENS

The Lennox ME43 fireplace features retractable

doors and firescreens in order to allow a wider

view of the fire and save space when the doors

are opened. To retract the doors, simply open

them at 90° and push them into the opening

on the side of the firebox. The same procedure

applies for the retractable firescreens. (see

Figure 2).

Note : Do not operate the fireplace with both fire-

screen and doors closed at the same time.

HOW TO USE THE OUTSIDE AIR REGISTER

(FIREPLACE)

The outside air register is located on the upper

part of the top louver. The outside air register

supplies oxygen to the fire and allows control

of the fire when the doors are closed. The fresh

air must come from outside the house (the

air intake must not draw air from inside the

house). This will minimize negative pressure

in the house. The more you slide the register

to the left, the more fresh air into the firebox

and the more accelerated combustion you will

get (see Figure 3). When starting a fire, the

register should always be fully opened.

FIREPLACE INSTALLATION

Preinstallation

Please Read Before Installing:

1. Before beginning the installation of your

fireplace, read these safety tips and instal-

lation instructions carefully to be sure you

understand them completely. Failure to

follow them could cause a fireplace malfunc-

tion resulting in serious bodily injury and/or

property damage.

2. The ME43 fireplace has been tested and listed

to UL and ULC standards by Warnock Hersey

International Inc. These instructions were

written to give you an outline for a fast and

safe installation and trouble-free operation.

PUSH TO

OPEN

PUSH TO OPEN

Figure 3