beautypg.com

Kohler K-3393 User Manual

Page 21

background image

Troubleshooting Guide (cont.)

Symptoms

Recommended Action
B.

Adjust the tank water level if it is too high.

C.

Clean the valve inlet, valve head, or supply line.

Flush the lines.

D.

An excessively high water supply pressure may

force the water through the fill valve. If required,

reduce external water pressure.

E.

Foreign particles may be lodged under the float

valve seal. Clear particles from valve seat.

F.

The float valve seal may be cracked or split.

Replace valve assembly.

5.

The fill

cycle is

noisy.

A.

Partially close the water supply shut-off valve if

the water pressure to the toilet is too high. Check

the toilet performance following any such

adjustment.

B.

Remove dirt or obstructions from the valve head.

Flush the lines.

6.

Pump

draws air

during

flush.

A.

The water line height may be incorrectly set. Set

the correct water line height. Adjust the screw

clockwise in order to raise the elevation of the

float and the full water line.

7.

No flush.

The pump

does not

operate.

A.

The pump is not plugged in or the electrical

power is not on. Plug the three-prong plug from

the pump into Class A GFCI, or turn on power to

toilet.

B.

The pump has locked out through its internal

thermal overload switch. Wait two minutes and

retry.

C.

The trip button is not plugged in. Plug modular

plug of the trip button wire into jack in trip

button housing.

D.

The trip button has failed. Replace the flush

button.

E.

The pump has failed. Replace the pump.

8.

Circuit

breaker

trips

frequently.

A.

Check that the circuit breaker is properly sized

and has no other electrical loads.

B.

If the circuit breaker trips while the pump is

disconnected, have an electrician correct the fault

in the wiring to the toilet.

Kohler Co.

21

1057478-5-C