Insufficient water supply

pressure/flow for operation.

Contact local water company.

Supply pressure must be a

minimum of 0.7 bar.

Note: If other appliances are

operating, pressure may drop

below 0.7 bar.

Power

Light

Heater

Setting

Low/Medium/

High

Probable Cause

Possible Remedy

Symptom

Low or No

flow

ON

Any

Other outlets (e.g. toilet,

garden hose, washing

machine, etc.) drawing

water while the shower is

being used.

Turn off other appliances whilst

shower is in use.

ON

Any

ON

Any

Cover not fitted correctly

causing Start/Stop

button not to operate.

Check Cover is cut and fitted

correctly. Check services

(electrical or plumbing) are not

interfering with location of Cover.

Inlet Valve faulty.

Replace.

Heater Tank excessively

scaled.

Replace. In hard water areas

consider the use of a water

softener.

ON

Any

Handset blocked.

Remove and clean.

ON

Any

ON

Any

ON

Any

Operation of

Temperature

Control has

little or no

effect on water

temperature.

II/III

ON

Handset or Inlet Filter

blocked.

Remove and clean.

Inlet Valve faulty.

Replace.

Heater Tank failure.

Replace.

Microswitch failure.

Replace.

II/III

ON

II/III

ON

II/III

ON

Water supply pipework or

inlet filter restricted by a

blockage or partial blockage.

Flush supply pipe. Clean Inlet

Filter.