beautypg.com

Kenmore 625.348460 User Manual

Page 25

background image

SERVICE TECH. INFORMATION

SECTION 5

25

5C. WATER FLOW THROUGH THE SOFTENER VALVE

BRINING AND BRINE RINSE CYCLES

After fill, timer/switch action allows the motor to turn the rotor and disc into

BRINING position. Water flow is directed to the nozzle. Suction, created by the

nozzle and venturi, draws brine from the salt storage tankand injects it into the resin

bed via the bottom distributor. Flow continues out the top distributor and to the

drain. Hard water is available at the valve outlet.

When the brine valve closes to end brine draw, water flow continues in the same

directions to slowly RINSE brine from the resin bed and to the drain.

BACKWASH (and ‘‘CLEAN’’) CYCLE

Timer/switch action again allows the motor to turn the

rotor & disc to place the valve in BACKWASH, stopping

water flow to the nozzle. Water is routed down and out

the bottom distributor, up through the bed, and out the

top distributor to the drain. The fast flow (controlled by

a flow plug in the drain fitting) flushes dirt, sediments,

iron deposits, remaining brine and hardness to the

drain.